![IBM xSeries 440 8687 Hardware Maintenance Manual Download Page 34](http://html1.mh-extra.com/html/ibm/xseries-440-8687/xseries-440-8687_hardware-maintenance-manual_2037961034.webp)
2.
You
must
create
a
static
partition
on
the
primary
server
prior
to
cabling
the
servers
together.
3.
Whenever
you
delete
the
static
partition,
you
must
remove
all
the
interconnected
cables
between
the
servers.
4.
When
two
servers
are
merged
together,
the
CD-ROM,
diskette
drive,
keyboard,
USB
ports,
mouse,
and
video
are
disabled
on
the
secondary
server.
Creating
a
static
partition:
Once
your
servers
are
installed
in
a
rack
cabinet,
return
here
and
complete
the
following
steps:
1.
Connect
a
pointing
device,
keyboard,
and
monitor
to
each
of
the
two
xSeries
440
servers.
2.
Using
the
two
short
SMP
Expansion
cables
that
come
with
your
servers,
complete
the
following
steps:
a.
Connect
one
end
of
the
first
SMP
Expansion
cable
to
port
3
of
the
top
SMP
Expansion
Module
on
the
primary
server;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
the
bottom
SMP
Expansion
Module
on
the
primary
server.
b.
Connect
one
end
of
the
second
SMP
Expansion
cable
to
port
3
of
the
top
SMP
Expansion
Module
on
the
secondary
server;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
the
bottom
SMP
Expansion
Module
on
the
secondary
server.
3.
Start
the
Configuration/Setup
Utility
program.
a.
Turn
on
a
server
and
watch
the
monitor
screen.
b.
When
the
message
Press
F1
for
Configuration/Setup
appears,
press
F1.
c.
Select
Advanced
Setup
from
the
menu;
then,
select
CPU
Options
and
enable
hyper-threading.
Notes:
1)
It
is
not
necessary
to
enable
hyper-threading
in
order
to
run
a
16-way
configuration;
however,
if
hyper-threading
is
desired,
it
must
be
enabled
on
both
servers.
2)
Any
changes
to
hyperthreading
settings
must
be
done
before
merging
the
systems.
d.
Save
and
Exit
setup.
4.
Insert
the
Remote
Supervisor
Adapter
diskette
into
the
diskette
drive.
5.
Use
the
utility
on
the
diskette
to
assign
an
IP
address
to
the
Remote
Supervisor
Adapter.
Note:
If
you
are
configuring
the
secondary
server
make
a
note
of
the
IP
address.
You
will
need
this
information
later
in
this
procedure.
6.
Exit
the
utility
and
turn
off
the
server.
7.
Repeat
steps
3
through
6
on
the
other
server.
8.
Connect
the
Remote
Supervisor
Adapters
of
each
server
to
the
network
or
use
the
Ethernet
crossover
cable
to
connect
them
to
each
other.
9.
Create
a
static
partition.
a.
Turn
on
the
primary
server
and
start
the
Configuration/Setup
Utility
as
described
in
step
3.
Note:
Turning
on
the
primary
server
may
also
turn
on
the
secondary
server.
This
is
an
acceptable
action.
The
secondary
server
does
not
need
to
be
turned
on,
but
it
does
need
to
be
connected
to
a
power
source.
22
xSeries
440
Type
8687:
Hardware
Maintenance
Manual
Summary of Contents for xSeries 440 8687
Page 1: ...xSeries 440 Type 8687 Hardware Maintenance Manual ERserver...
Page 2: ......
Page 3: ...xSeries 440 Type 8687 Hardware Maintenance Manual ERserver...
Page 6: ...iv xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 12: ...x xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 26: ...14 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 62: ...50 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 80: ...68 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 162: ...150 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 206: ...194 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 210: ...Figure A 1 2 4 5 6 7 8 9 9 3 10 198 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 223: ...Related service information 211...
Page 224: ...212 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 225: ...Related service information 213...
Page 226: ...214 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 227: ...Related service information 215...
Page 228: ...216 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 229: ...Related service information 217...
Page 230: ...218 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 240: ...228 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 241: ...Related service information 229...
Page 242: ...230 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 243: ...Related service information 231...
Page 250: ...238 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 256: ...244 xSeries 440 Type 8687 Hardware Maintenance Manual...
Page 257: ......