Table
4.
NetWare
driver
messages
for
the
Ethernet
controller
(continued)
Message
Description
LAN
adapter
at
slot
nnnn
(Port
0x
aa
)
failed
to
reset.
Check
the
state
of
the
adapter.
Explanation:
The
adapter
that
you
specified
could
not
be
initialized.
Action:
1.
Load
the
driver
for
the
supported
adapter.
2.
Check
that
the
adapter
is
seated
properly
in
the
slot
and
try
loading
the
AFT
module
again.
If
the
problem
persists,
contact
your
network
supplier.
AFT
is
not
supported
on
this
version
of
NetWare
™
.
Explanation:
The
NetWare
on
the
server
is
not
a
version
supported
by
AFT.
Action:
Load
and
bind
AFT
only
on
supported
versions
of
NetWare
(currently
version
4.11
and
above).
Failed
to
allocate
resources
tags.
Explanation:
An
unknown
error
has
occurred
when
trying
to
allocate
needed
resources
for
the
AFT
module.
Action:
Check
server
configuration.
If
the
problem
persists,
contact
your
network
supplier.
Please
unload
all
LAN
drivers
before
unloading
AFT.NLM.
Explanation:
An
attempt
was
made
to
unload
the
AFT.NLM
module
before
unloading
the
adapter
driver.
Action:
Unload
the
adapter
driver
before
unloading
the
AFT
module.
NDIS
4.0
Windows
driver
messages
This
section
contains
the
error
messages
for
the
NDIS
4.0
drivers.
The
explanation
and
recommended
action
are
included
with
each
message.
Table
5.
NDIS
(Windows
NT
or
Windows
2000)
driver
messages
for
the
Ethernet
controller
Error
code
(hex)
Description
0x00
Explanation:
The
driver
could
not
register
the
specified
interrupt.
Action:
Using
the
Configuration/Setup
Utility
program,
make
sure
that
a
PCI
interrupt
is
assigned
to
your
Ethernet
card,
and
that
Ethernet
is
enabled.
0x01
Explanation:
One
of
the
PCI
cards
did
not
get
the
required
resources.
Action:
Using
the
Configuration/Setup
Utility
program,
make
sure
that
a
PCI
interrupt
is
assigned
to
your
Ethernet
card,
and
that
Ethernet
is
enabled.
0x02
Explanation:
Bad
node
address
(multicast
address).
Action:
Make
sure
the
locally
administered
address
is
valid,
if
one
is
specified.
The
address
can
not
be
a
multicast
address.
0x03
Explanation:
Failed
self-test.
Action:
Make
sure
a
cable
is
attached
to
the
Ethernet
connector.
0x0D
Explanation:
Could
not
allocate
enough
memory
for
transmit
queues.
Action:
1.
From
the
Windows
NT
desktop,
select
Start
”
Control
Panel
”
Networks
”
Adapters
.
2.
Select
your
IBM
Ethernet
adapter
from
the
list.
3.
Select
Properties
”
Advanced
.
4.
Lower
the
resource
values
that
apply
to
the
transmit
queue.
Diagnostics
21
Summary of Contents for xSeries 200
Page 1: ...xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 96: ...88 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 106: ...98 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 121: ...Related service information 113 ...
Page 122: ...114 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 123: ...Related service information 115 ...
Page 124: ...116 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 125: ...Related service information 117 ...
Page 126: ...118 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 127: ...Related service information 119 ...
Page 128: ...120 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 138: ...130 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 139: ...Related service information 131 ...
Page 140: ...132 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 147: ......