Table
3.
Ethernet
troubleshooting
chart
(continued)
Ethernet
controller
problem
Suggested
Action
Data
is
incorrect
or
sporadic.
Check
the
following:
v
Make
sure
that
you
are
using
Category
5
cabling
when
operating
the
server
at
100
MBps.
v
Make
sure
that
the
cables
do
not
run
close
to
noise-inducing
sources
like
fluorescent
lights.
The
Ethernet
controller
stopped
working
when
another
adapter
was
added
to
the
server.
Check
the
following:
v
Make
sure
that
the
cable
is
connected
to
the
Ethernet
controller.
v
Make
sure
that
your
PCI
server
BIOS
is
current.
v
Reseat
the
adapter.
v
Determine
if
the
IRQ
setting
assigned
to
the
Ethernet
adapter
is
also
assigned
to
another
device
in
the
Configuration/Setup
Utility
program.
Although
interrupt
sharing
is
allowed
for
PCI
devices,
some
devices
do
not
function
well
when
they
share
an
interrupt
with
a
dissimilar
PCI
device.
Try
changing
the
IRQ
assigned
to
the
Ethernet
adapter
or
the
other
device.
The
Ethernet
controller
stopped
working
without
apparent
cause.
Check
the
following:
v
Run
diagnostics
for
the
Ethernet
controller.
v
Try
a
different
connector
on
the
hub.
v
Reinstall
the
device
drivers.
Refer
to
your
operating
system
documentation
and
to
the
ServerGuide
information.
Ethernet
controller
messages
The
integrated
Ethernet
controller
might
display
messages
from
the
following
device
drivers:
v
Novell
NetWare
™
or
IntraNetWare
system
open
data-link
interface
(ODI)
v
Network
driver
interface
specification
(NDIS)
adapter
for
level
4.0
(Windows
NT)
Novell
NetWare
or
IntraNetWare
system
ODI
driver
teaming
messages
This
section
provides
explanations
of
the
error
messages
for
the
Novell
NetWare
or
IntraNetWare
system
ODI
driver,
and
suggested
actions
to
resolve
each
problem.
Table
4.
NetWare
driver
messages
for
the
Ethernet
controller
Message
Description
Couldn’t
allocate
resources.
Explanation:
An
unknown
error
has
occurred
when
trying
to
allocate
needed
resources
for
the
AFT
Module.
Action:
v
Check
the
server
configuration.
If
the
problem
persists,
contact
your
network
supplier.
v
Verify
that
the
Ethernet
controller
is
enabled.
If
the
Ethernet
controller
is
enabled,
run
the
diagnostic
programs.
AFT
group
for
primary
adapter
in
slot
nnn
already
exists.
Explanation:
An
attempt
was
made
to
rebind
an
adapter
already
in
an
AFT
group.
Action:
Check
the
AFT
slot
numbers
for
existing
AFT
teams.
If
the
problem
persists,
contact
your
network
supplier.
Diagnostics
19
Summary of Contents for xSeries 200
Page 1: ...xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 96: ...88 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 106: ...98 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 121: ...Related service information 113 ...
Page 122: ...114 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 123: ...Related service information 115 ...
Page 124: ...116 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 125: ...Related service information 117 ...
Page 126: ...118 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 127: ...Related service information 119 ...
Page 128: ...120 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 138: ...130 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 139: ...Related service information 131 ...
Page 140: ...132 xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual ...
Page 147: ......