4.
Carefully turn the server on its side so that it is lying flat, with the system
board facing up.
Attention:
Do not allow the server to fall over.
5.
Touch the static-protective package that contains the microprocessor to any
unpainted metal surface on the server. Then, remove the microprocessor from
the package.
6.
Remove the protective cover, tape, or label from the surface of the
microprocessor socket, if any is present.
7.
Rotate the release lever on the microprocessor socket to the fully open
position.
Attention:
Make sure that the release lever on the microprocessor socket is
in the fully open position before you insert the microprocessor in the socket.
Failure to do so might result in permanent damage to the microprocessor,
microprocessor socket, and system board.
8.
Carefully grasp the microprocessor and place the microprocessor into the
microprocessor socket.
Note:
To maintain correct orientation between the microprocessor and the
microprocessor socket during installation, observe the following information:
v
The microprocessor has two notches that are keyed to two tabs on the sides
of the socket.
v
A triangle-shaped indicator on one corner of the microprocessor points to a
45-degree angle on the system board.
v
Do not use excessive force when you press the microprocessor into the
socket.
9.
Close the microprocessor bracket frame; then, close the microprocessor
retention latch and lock it securely in place.
10.
Install the heat sink:
Microprocessor
Alignment
marks
Microprocessor
bracket frame
Microprocessor
release lever
System board
Figure 45. Microprocessor bracket frame and retention latch engagement for 5U server
models with hot-swap power supplies
Chapter 2. Installing optional devices
69
Summary of Contents for x3100 M5 Type 5457
Page 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Page 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Page 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Page 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 679: ...Taiwan Class A compliance statement Notices 663 ...
Page 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 687: ......
Page 688: ... Part Number 00V9791 Printed in USA 1P P N 00V9791 ...