806f050d-0404ffff
Array [ComputerSystemElementName] is in critical condition. (Drive 4)
Explanation:
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0404ffff or 0x806f050d0404ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0174
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0405ffff
Array [ComputerSystemElementName] is in critical condition. (Drive 5)
Explanation:
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0405ffff or 0x806f050d0405ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0174
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0404ffff • 806f050d-0405ffff
434
System x3100 M5 Type 5457: Installation and Service Guide
Summary of Contents for x3100 M5 Type 5457
Page 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Page 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Page 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Page 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 679: ...Taiwan Class A compliance statement Notices 663 ...
Page 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 687: ......
Page 688: ... Part Number 00V9791 Printed in USA 1P P N 00V9791 ...