806f010c-2003ffff
Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 3)
Explanation:
This message is for the use case when an implementation has detected a Memory uncorrectable error.
May also be shown as 806f010c2003ffff or 0x806f010c2003ffff
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0138
SNMP Trap ID:
41
Automatically notify Support:
Yes
User response:
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different
memory channel or microprocessor.
3.
If the problem follows the DIMM, replace the failing DIMM.
4.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
5.
(Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any
damaged pins. If a damage is found, replace the system board.
6.
(Trained technician only) Replace the affected microprocessor.
7.
Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server
firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the
server.
8.
(Trained Service technician only) Replace the affected microprocessor.
806f010c-2004ffff
Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 4)
Explanation:
This message is for the use case when an implementation has detected a Memory uncorrectable error.
May also be shown as 806f010c2004ffff or 0x806f010c2004ffff
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0138
SNMP Trap ID:
41
Automatically notify Support:
Yes
User response:
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different
memory channel or microprocessor.
3.
If the problem follows the DIMM, replace the failing DIMM.
4.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
5.
(Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any
damaged pins. If a damage is found, replace the system board.
6.
(Trained technician only) Replace the affected microprocessor.
806f010c-2003ffff • 806f010c-2004ffff
Appendix A. Integrated management module II (IMM2) error messages
411
Summary of Contents for x3100 M5 Type 5457
Page 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Page 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Page 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Page 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 679: ...Taiwan Class A compliance statement Notices 663 ...
Page 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Page 687: ......
Page 688: ... Part Number 00V9791 Printed in USA 1P P N 00V9791 ...