7.
Remove the two screws that secure the power-supply cage to the chassis; the
two screws are located in the front of the hot-swap power supply cage.
8.
Remove the other four screws that also secure the power-supply cage to the
chassis; then, slide the cage toward the front of the server to disengage the
retaining clips from the top of the chassis and lift the cage out of the chassis.
Power cable connector
Power interposer
cable connector
Figure 211. Power cable removal from backplane for 5U server model with hot-swap power
supplies (2)
Hot-swap
power-supply cage
Screws
Figure 212. Hot-swap power supply cage screw removal for 5U server model with hot-swap
power supplies
296
System x3100 M5 Type 5457: Installation and Service Guide