Hardware Maintenance Manual: xSeries 340 Model 6RY
Network driver interface specification 2.01 (OS/2) driver
messages
This section provides explanations of the error messages for the NDIS 2.01 (OS/2)
drivers, and suggested actions to resolve each problem.
PCNTNW-NW-165
The device was not found at IOADDRESS.
Explanation:
The Ethernet controller cannot be found at the I/O address
specified.
Action:
The Ethernet controller does not require a parameter for the I/O
address. Remove the I/O address parameter.
PCNTNW-NW-167
PCI scan specified, device not found.
Explanation:
The driver cannot locate the Ethernet controller on the PCI bus.
Action:
Verify that the Ethernet controller is enabled. If the problem persists,
go to “Starting the diagnostic programs” on page 14 to run the diagnostic
programs.
PCNTNW-NW-180
The DMA parameter is not necessary for PCI device.
Explanation:
The Ethernet controller does not require a DMA setting.
Action:
None necessary, message is for information only.
Table 3. NDIS 2.01 (OS/2) driver messages for the Ethernet controller.
PCNTND-1 Unable to open the Protocol Manager
.
Explanation:
The NDIS stack is not configured correctly. Action: Check
and correct your configuration.
PCNTND-6
Out of memory while allocating buffers.
Explanation:
The driver could not allocate the requested buffers. Action:
Check your system configuration. Edit the PROTOCOL.INI file to reduce the number of
Txbuffers and Rxbuffers specified for the driver.
PCNTND-7
A Protocol Manager device error occurred.
Explanation:
The NDIS stack is not configured correctly.
Action:
Check and correct your configuration.
PCNTND-8
Bad status for the Protocol Manager.
Explanation:
The NDIS stack is not configured correctly in the PROTOCOL.INI file.
Action:
Check and correct your configuration.
PCNTND-9
Cannot find the PROTOCOL.INI entry.
Explanation:
The NDIS stack is not configured correctly in the PROTOCOL.INI file.
Action:
Check and correct your configuration.
PCNTND-10
The Protocol Manager Input Output Control (IOCTL) failed.
Explanation:
The NDIS stack is not configured correctly in the PROTOCOL.INI file.
Action:
Check and correct your configuration.
PCNTND-11
Protocol Manager registration failed.
Explanation:
The NDIS stack is not configured correctly. Action: Check and correct
your configuration.
Table 2. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller.
Summary of Contents for x 340 Series
Page 1: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 46: ...38 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 112: ...104 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 140: ...132 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 157: ...Related service information 149...
Page 158: ...150 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 159: ...Related service information 151...
Page 160: ...152 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 161: ...Related service information 153...
Page 162: ...154 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 163: ...Related service information 155...
Page 164: ...156 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 177: ...Related service information 169...
Page 178: ...170 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 179: ...Related service information 171...
Page 187: ......