![IBM x 340 Series Hardware Maintenance Manual Download Page 29](http://html1.mh-extra.com/html/ibm/x-340-series/x-340-series_hardware-maintenance-manual_4277654029.webp)
Diagnostics
21
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the
Link Support Layer (LSL).
Explanation:
An error occurred while the driver was trying to register with
the LSL.
Action:
Check the version of the NetWare or IntraNetWare Operating
System. Make sure that this driver is correct for the version of NetWare or
IntraNetWare that you are using. Restart the server.
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free
Count.
Explanation:
The MSMTx Free Count is not initialized correctly.
Action:
Restart the server. If the problem persists, go to “Starting the
diagnostic programs” on page 14 to run the diagnostic programs. .
PCNTNW-NW-086
The driver parameter block is too small.
Explanation:
The driver parameter block is too small.
Action:
Restart the server. If the problem persists, go to “Starting the
diagnostic programs” on page 14 to run the diagnostic programs.
PCNTNW-NW-087
The media parameter block is too small.
Explanation:
The driver media parameter block is too small.
Action:
Restart the server. If the problem persists, go to “Starting the
diagnostic programs” on page 14 to run the diagnostic programs.
PCNTNW-NW-091
The hardware configuration conflicts.
Explanation:
You tried to load a new frame type for the existing controller.
The hardware assumptions made in doing so are incorrect. This error can
also occur if you try to specify a mode (such as, redundancy) that conflicts
with another specified mode. Action: Make sure that
your hardware configuration matches the software settings.
PCNTNW-NW-126
The group bit in the node address override was cleared.
Explanation:
The IEEE address has a group bit that indicates that an address
belongs to a group of stations. This bit is used only as a destination address;
it cannot be used as a source address. You tried to enter a source address
with this bit set. The driver cleared the group bit of the source address.
Action:
None necessary, message is for information only.
PCNTNW-NW-127
The local bit in the node address override was set.
Explanation:
The local bit in the IEEE address format indicates that the
addresses are being managed locally. If you use the node address override
capabilities of this driver to enter a new address, the local bit must be set.
You entered an address without the local bit set. The driver has set the local
bit.
Action:
None necessary, message is for information only.
PCNTNW-NW-164
The device was not found.
Explanation:
The driver cannot find an Ethernet controller in the server.
Action:
Verify that the Ethernet controller is enabled. If the Ethernet
controller is enabled, go to “Starting the diagnostic programs” on page 14 to
run the diagnostic programs.
Table 2. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller.
Summary of Contents for x 340 Series
Page 1: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 46: ...38 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 112: ...104 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 140: ...132 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 157: ...Related service information 149...
Page 158: ...150 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 159: ...Related service information 151...
Page 160: ...152 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 161: ...Related service information 153...
Page 162: ...154 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 163: ...Related service information 155...
Page 164: ...156 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 177: ...Related service information 169...
Page 178: ...170 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 179: ...Related service information 171...
Page 187: ......