SCSI error codes
Temperature error messages
Error Code
FRU/Action
All SCSI Errors
One or more of
the following might be causing the problem:
•
A failing SCSI device (adapter, drive,
controller)
•
An improper SCSI configuration or SCSI
termination jumper setting
•
Duplicate SCSI IDs in the same SCSI
chain
•
A missing or improperly installed SCSI
terminator
•
A defective SCSI terminator
•
An improperly installed cable
•
A defective cable
1.
External SCSI devices must be powered-on before you power-on
the server.
2.
The cables for all external SCSI devices are connected correctly.
3.
If you have attached an external SCSI device to the server, make
sure the external SCSI termination is set to automatic.
4.
The last device in each SCSI chain is terminated correctly.
5.
The SCSI devices are configured correctly.
Message
Action
DASD bank 2 Over Temperature
(level-
critical; Direct Access Storage Device bay
"X" was over temperature)
1.
Ensure system is being properly cooled
; see “Temperature
DASD Over recommened Temperature
(sensor X)
(level-warning; DASD
bay "X" had over temperature condition)
1.
Ensure system is being properly cooled
; see “Temperature
DASD under recommended temperature
(sensor X)
(level-warning; direct access
storage device bay "X" had under
temperature condition)
1.
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 3.
DASD 1 Over Temperature
(level-critical;
sensor for DASD1 reported temperature
over recommended range)
1.
Ensure system is being properly cooled
; see “Temperature
Power Supply "X" Temperature Fault
(level-critical; power supply "x"had over
temperature condition)
1.
Ensure system is being properly cooled;
see “Temperature
2.
Replace Power Supply "X"
System board is over recommended
temperature
(level-warning; system
board is over recommended temperature)
1.
Ensure system is being properly cooled
; see “Temperature
2.
Replace system board
System board is under recommended
temperature
(level-warning; system
board is under recommended temperature)
1.
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 3.
System over temperature for CPU "X"
(level-warning; CPU "X" reporting over
temperature condition)
1.
Ensure system is being properly cooled; see “Temperature
checkout” on page 28.
Summary of Contents for x 340 Series
Page 1: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 46: ...38 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 112: ...104 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 140: ...132 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 157: ...Related service information 149...
Page 158: ...150 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 159: ...Related service information 151...
Page 160: ...152 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 161: ...Related service information 153...
Page 162: ...154 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 163: ...Related service information 155...
Page 164: ...156 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 177: ...Related service information 169...
Page 178: ...170 Hardware Maintenance Manual xSeries 340 Model 6RY...
Page 179: ...Related service information 171...
Page 187: ......