52
DS6000 Series: Concepts and Architecture
A physical FICON path is established when the DS6800 port sees light on the FICON fiber
(for example, a cable is plugged in to a DS6800 host adapter, or a processor, or the DS6800
is powered on, or a path is configured online by OS/390). At this time, logical paths are
established through the FICON port between the host and some or all of the LCUs in the
DS6800, controlled by the HCD definition for that host. This happens for each physical path
between a zSeries CPU and the DS6800. There may be multiple system images in a CPU.
Logical paths are established for each system image. The DS6800 then knows which FICON
paths can be used to communicate between each LCU and each host.
Provided you have the correct maintenance level, all major zSeries operating systems should
support preferred path (z/OS, z/VM, VSE/ESA™, TPF).
CUIR
Control Unit Initiated Reconfiguration (CUIR) prevents loss of access to volumes in zSeries
environments due to wrong path handling. This function automates channel path
management in zSeries environments in support of selected DS6800 service actions.
Control Unit Initiated Reconfiguration is available for the DS6800 when operating in the z/OS
and z/VM environments. The CUIR function automates channel path vary on and vary off
actions to minimize manual operator intervention during selected DS6800 service actions.
CUIR allows the DS6800 to request that all attached system images set all paths required for
a particular service action, to the offline state. System images with the appropriate level of
software support will respond to such requests by varying off the affected paths, and either
notifying the DS6800 subsystem that the paths are offline, or that it cannot take the paths
offline. CUIR reduces manual operator intervention and the possibility of human error during
maintenance actions, at the same time reducing the time required for the maintenance. This
is particularly useful in environments where there are many systems attached to a DS6800.
3.3 Disk subsystem RAS
The DS6000 currently supports only RAID-5 and RAID-10. It does not support non-RAID
configurations of disks (JBOD - just a bunch of disks).
3.3.1 RAID-5 overview
RAID-5 is one of the most commonly used forms of RAID protection.
RAID-5 theory
The DS6000 series supports RAID-5 arrays. RAID-5 is a method of spreading volume data
plus parity data across multiple disk drives. RAID-5 provides faster performance by striping
data across a defined set of DDMs. Data protection is provided by the generation of parity
information for every stripe of data. If an array member fails, then its contents can be
regenerated by using the parity data.
RAID-5 implementation in the DS6000
In a DS6000, a RAID-5 array built on one array site will contain either three disks or four disks,
depending on whether the array site chosen had a pre-allocated spare. A three disk array
effectively uses 1 disk for parity, so it is referred to as a 2+P array (where the P stands for
parity). The reason only three disks are available to a 2+P array is that the fourth disk in the
array site used to build the array, was used as a spare. This can be referred to as a 2+P+S
Note: CUIR support will be included in a future release of microcode.
Summary of Contents for System storage DS6000 Series
Page 2: ......
Page 5: ...iii...
Page 6: ...iv DS6000 Series Concepts and Architecture...
Page 18: ...xvi DS6000 Series Concepts and Architecture...
Page 24: ...xxii DS6000 Series Concepts and Architecture...
Page 26: ...2 DS6000 Series Concepts and Architecture...
Page 44: ...20 DS6000 Series Concepts and Architecture...
Page 46: ...22 DS6000 Series Concepts and Architecture...
Page 68: ...44 DS6000 Series Concepts and Architecture...
Page 88: ...64 DS6000 Series Concepts and Architecture...
Page 136: ...112 DS6000 Series Concepts and Architecture...
Page 138: ...114 DS6000 Series Concepts and Architecture...
Page 218: ...194 DS6000 Series Concepts and Architecture...
Page 242: ...218 DS6000 Series Concepts and Architecture...
Page 266: ...242 DS6000 Series Concepts and Architecture...
Page 298: ...274 DS6000 Series Concepts and Architecture...
Page 352: ...328 DS6000 Series Concepts and Architecture...
Page 392: ...368 DS6000 Series Concepts and Architecture...
Page 396: ...372 DS6000 Series Concepts and Architecture...
Page 404: ...DS6000 Series Concepts and Architecture DS6000 Series Concepts and Architecture...
Page 405: ......