BCS
ECS
Explanation
Action
07
0C
Online/Rebuild drives are not responding, and a
drive was found at the incorrect SCSI ID.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and cable
connections that were switched or moved; then,
press F4 to retry.
Note: Pressing F4 might not correct the
problem. If you do not return the drives and
cables to the previous configuration, the
message might return.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be faulty. Identify and replace the faulty
drives; then, press F5 to accept the changes.
3. To modify the configuration and accept the
rearrangement of the physical drives, press F6.
To exit without making changes, press F10.
07
1C
Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding, and a
drive was found at the incorrect SCSI ID.
07
2C
Online/Rebuild and Ready/Standby drives are
not responding, and a drive was found at the
incorrect SCSI ID.
07
3C
Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not
responding, and a drive was found at the
incorrect SCSI ID.
07
4C
Online/Rebuild drives are not responding, and a
drive was found at the incorrect SCSI ID, and
unidentified drives were found.
07
5C
Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding, a drive
was found at the incorrect SCSI ID, and
unidentified drives were found.
07
6C
Online/Rebuild and Ready/Standby drives are
not responding, a drive was found at the
incorrect SCSI ID, and unidentified drives were
found.
07
7C
Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not
responding, a drive was found at the incorrect
SCSI ID, and unidentified drives were found.
07
18
Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and cable
connections that were switched or moved; then,
press F4 to retry.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be faulty. Identify and replace the faulty
drives; then, press F5 to accept the changes.
To exit without making changes, press F10.
07
28
Online/Rebuild and Ready/Standby drives are
not responding.
07
38
Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not
responding.
07
48
Online/Rebuild drives are not responding, and
unidentified drives were found.
07
58
Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding, and
unidentified drives were found.
07
68
Online/Rebuild and Ready/Standby drives are
not responding, and unidentified drives were
found.
07
78
Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not
responding, and unidentified drives were found.
09
00
No error occurred.
No action is required. Press F10 to exit without
making any changes.
Chapter 18. Solving ServeRAID problems
145
Summary of Contents for ServeRAID-4 Ultra160 Series
Page 1: ...IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller SC25 P258 10...
Page 2: ......
Page 3: ...IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller SC25 P258 10...
Page 12: ...x IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 18: ...xvi IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 19: ...Part 1 Installation and configuration Copyright IBM Corp 2001 1...
Page 20: ...2 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 32: ...14 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 44: ...26 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 58: ...40 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 60: ...42 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 69: ...Part 2 Utility programs Copyright IBM Corp 2001 51...
Page 70: ...52 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 74: ...56 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 96: ...78 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 107: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2001 89...
Page 108: ...90 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 112: ...94 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 116: ...98 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 124: ...106 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 140: ...122 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 146: ...128 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 147: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2001 129...
Page 148: ...130 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 150: ...132 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 152: ...134 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 184: ...166 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 185: ...Part 5 Appendixes Copyright IBM Corp 2001 167...
Page 186: ...168 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 200: ...182 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Page 207: ......