Step 1540-6
The failure may be caused by the last pair of memory modules installed or the
memory card. To isolate the failing FRU, do the following:
1. Turn the power off and remove the power cable.
2. Exchange the last memory module pair installed.
3. Reinstall the power cable.
4. Turn the power on.
Does the system stop with code E1F2, E1F3, STBY or 4BA00830 displayed on
the operator panel?
NO
Go to “Step 1540-8” on page 2-40.
YES
Go to “Step 1540-7” on page 2-39.