Step 1240-9
The failure may be caused by the last pair of memory modules installed or the
memory card. To isolate the failing FRU, do the following:
1. Turn the power off.
2. Exchange the last memory module pair installed.
3. Turn the power on.
Does the system stop with a memory checkpoint displayed on the operator
panel?
NO
Go to “Step 1240-11” on page 2-22.
YES
Go to “Step 1240-10.”
Step 1240-10
One of the FRUs remaining in the system unit is defective.
1. Turn the power off.
2. Exchange the following FRUs in the order listed.
a. Memory card
b. System board
c. Processor card(s)
3. Turn the power on.
Does the system stop with a memory checkpoint displayed on the operator
panel?
NO
Go to "Map 0410: Repair Checkout" in the
IBM RS/6000 Diagnostic
Information for Multiple Bus Systems.
YES
Reinstall the original FRU.
Repeat this step until the defective FRU is identified or all the FRUs have
been exchanged.
If the symptom did not change and all the FRUs have been exchanged,
go to “MAP 1540: Minimum Configuration” on page 2-31.
Chapter 2. Maintenance Analysis Procedures
2-21
Summary of Contents for RS/6000 7043 260
Page 1: ...RS 6000 7043 Model 260 IBM Service Guide SA38 0554 00...
Page 6: ...vi Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 18: ...xviii Service Guide...
Page 20: ...Rear View 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 10 17 18 19 1 2 Service Guide...
Page 92: ...2 60 Service Guide...
Page 198: ...3 To remove the rear cover lift the cover up and away from the system 7 6 Service Guide...
Page 200: ...b Slide the covers to the rear and remove 7 8 Service Guide...
Page 220: ...3 Locate the battery on the I O board Battery P N 15F8409 7 28 Service Guide...
Page 237: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 238: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 20 22 23 24 25 8 2 Service Guide...
Page 312: ...B 6 Service Guide...
Page 318: ...X 6 Service Guide...
Page 321: ......