Step 1540-4
No failure was detected with this configuration.
1. Turn the power off and remove the power cable.
2. Reinstall the second processor card.
3. Plug in the power cable (and wait for OK on the operator panel display).
4. Turn the power on.
Does the system stop with code E1F2, E1F3, STBY or 4BA00830 displayed on
the operator panel?
NO
One of the FRUs remaining in the system unit is defective.
In the following order, exchange the FRUs that have not been exchanged:
1. Processor card (last one installed)
2. System board
3. I/O board (See notes on 2-1.)
Repeat this step until the defective FRU is identified or all the FRUs have
been exchanged.
If the symptom did not change and all the FRUs have been exchanged,
call your service support person for assistance.
If the symptom changed, check for loose cards and obvious problems. If
you do not find a problem, return to “Step 1540-1” on page 2-32 and
follow the instructions for the new symptom.
YES
Go to “Step 1540-5” on page 2-37.
2-36
Service Guide
Summary of Contents for RS/6000 7043 260
Page 1: ...RS 6000 7043 Model 260 IBM Service Guide SA38 0554 00...
Page 6: ...vi Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 18: ...xviii Service Guide...
Page 20: ...Rear View 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 10 17 18 19 1 2 Service Guide...
Page 92: ...2 60 Service Guide...
Page 198: ...3 To remove the rear cover lift the cover up and away from the system 7 6 Service Guide...
Page 200: ...b Slide the covers to the rear and remove 7 8 Service Guide...
Page 220: ...3 Locate the battery on the I O board Battery P N 15F8409 7 28 Service Guide...
Page 237: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 238: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 20 22 23 24 25 8 2 Service Guide...
Page 312: ...B 6 Service Guide...
Page 318: ...X 6 Service Guide...
Page 321: ......