Memory PD Bits
The following table expands the firmware error code 25Cyyxxx on page 3-9, where
yy is the PD values in the table below and xxx are the last three digits of the error
code. Use these values to identify the type of memory that generated the error.
If you replace FRUs and the problem is still not corrected, go to “MAP 1540:
Minimum Configuration” on page 2-31 unless otherwise indicated in the tables.
Table
3-2. Memory Module PD bits
PD
value
Size
Clock Cycle
(nsecs)
Parity/
ECC
28
512MB
10
ECC
2A
512MB
8
ECC
38
128MB
10
ECC
3A
128MB
8
ECC
48
64MB
10
ECC
4A
64MB
8
ECC
58
32MB
10
ECC
5A
32MB
8
ECC
68
256MB
10
ECC
6A
256MB
8
ECC
Note: Memory modules must be installed in pairs.
3-30
Service Guide
Summary of Contents for RS/6000 7043 260
Page 1: ...RS 6000 7043 Model 260 IBM Service Guide SA38 0554 00...
Page 6: ...vi Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 18: ...xviii Service Guide...
Page 20: ...Rear View 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 10 17 18 19 1 2 Service Guide...
Page 92: ...2 60 Service Guide...
Page 198: ...3 To remove the rear cover lift the cover up and away from the system 7 6 Service Guide...
Page 200: ...b Slide the covers to the rear and remove 7 8 Service Guide...
Page 220: ...3 Locate the battery on the I O board Battery P N 15F8409 7 28 Service Guide...
Page 237: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 238: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 20 22 23 24 25 8 2 Service Guide...
Page 312: ...B 6 Service Guide...
Page 318: ...X 6 Service Guide...
Page 321: ......