Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
40111182 A low PCI + 5.0 voltage reading
detected.
1. Replace power supply
2. Replace I/O expansion board.
40111192 A low PCI + 3.3 voltage reading
detected.
1. Replace power supply
2. Replace I/O expansion board.
401111B2 A low PCI + 12.0 voltage reading
detected.
1. Replace power supply
2. Replace I/O expansion board.
401111C2 A low PCI - 12.0 voltage reading
detected.
1. Replace power supply
2. Replace I/O expansion board.
40112022 A high 5.0 voltage reading
detected.
1. Replace power supply.
2. Replace processor card.
40112023 A high 1.8 voltage reading
detected.
1. Replace power supply.
2. Replace processor card.
40112032 A high 3.3 voltage reading
detected.
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
40112033 A high 2.5 voltage reading
detected.
1. Replace power supply.
2. Replace processor card.
40112052 A high +12 voltage reading
detected.
1. Replace power supply.
2. I/O board. (See note on page 93.)
40112061 A high -12 voltage reading
detected.
1. Replace power supply.
2. I/O board. (See note on page 93.)
40112062 A low 1.8 voltage reading
detected.
1. Replace power supply.
2. Replace processor card.
40112063 A critically low 1.8 voltage reading
detected.
1. Replace power supply.
2. Replace processor card.
40112064 A critically high 1.8 voltage
reading detected.
1. Replace power supply.
2. Replace processor card.
40112065 A critically low 2.5 voltage reading
detected.
1. Replace power supply.
2. Replace processor card.
40112066 A critically high 2.5 voltage
reading detected.
1. Replace power supply.
2. Replace processor card.
40112082 A low 5.0 voltage reading
detected.
1. Replace power supply.
2. Replace processor card.
40112092 A low 3.3 voltage reading
detected.
1. Replace power supply.
2. I/O board. (See note on page 93.)
40112093 A low 5.0 voltage reading
detected.
1. Replace power supply.
2. Replace processor card.
401120B2 A low +12 voltage reading
detected.
1. Replace power supply.
2. I/O board. (See note on page 93.)
401120C2 A low -12 voltage reading
detected.
1. Replace power supply.
2. I/O board. (See note on page 93.)
40200001 An unknown cooling problem
detected.
Check/replace system fans.
Chapter 5. Error Code to FRU Index
119
Summary of Contents for RS/6000 44P Series 270
Page 1: ...RS 6000 44P Series Model 270 Service Guide SA38 0572 02 ...
Page 10: ...x Service Guide ...
Page 14: ...xiv Service Guide ...
Page 16: ...xvi Service Guide ...
Page 20: ...Rear View 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 10 17 18 19 2 Service Guide ...
Page 44: ...26 Service Guide ...
Page 164: ...146 Service Guide ...
Page 204: ...186 Service Guide ...
Page 247: ...b Slide the covers to the rear and remove Chapter 9 Removal and Replacement Procedures 229 ...
Page 288: ...270 Service Guide ...
Page 290: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 20 22 23 24 25 272 Service Guide ...
Page 294: ...Keyboards and Mouse 276 Service Guide ...
Page 296: ...Keyboards and Mouse Black 278 Service Guide ...
Page 298: ...Power Cables 1 2 3 4 5 6 7 8 9 10 11 280 Service Guide ...
Page 300: ...282 Service Guide ...
Page 302: ...284 Service Guide ...
Page 304: ...286 Service Guide ...
Page 310: ...292 Service Guide ...
Page 338: ...320 Service Guide ...
Page 345: ......
Page 346: ... Printed in U S A September 2001 SA38 0572 02 ...