Problem
FRU/Action
Full Charge-A or Full
Charge-B LED (battery
CRU) is off.
1. Power-on Controller
and allow batteries to
charge for 24 hours
until the Full Charge
LEDs are on.
2. Battery CRU
3. Both power supplies
No power to controller (all
power LEDs off)
1. Check power
switches and power
cords
2. Power supplies
Power Supply LED is off.
1. Check and reseat
power supply
2. Check for overheating.
Wait ten minutes for
the power supply CRU
to cool down. See
“Recovering from a
Power Supply
Shutdown” on
page 33.
3. Power supply CRU
Power Supply CRUs LED
are on, but all other CRU
LEDs are off.
1. DC power harness