Surveillance takes effect immediately after the parameters are set from the service
processor menus.
If operating system surveillance is enabled (and system firmware has passed control to
the operating system), and the service processor does not detect any heartbeats from
the operating system within the surveillance delay period, the service processor
assumes the system is hung. The machine is left powered on and the service processor
enters standby phase, displaying the operating system surveillance failure code on the
operator panel. If call-out is enabled, the service processor calls to report the failure.
Call Out
The service processor can call out when it detects one of the following conditions:
v
System firmware surveillance failure
v
Operating system surveillance failure (if supported by the operating system)
v
Critical environmental failures
v
Restarts
To enable the call-out feature, do the following:
1. Have a modem connected to serial port 1 or 2.
2. Set up the following using the service processor menus or diagnostic service aids:
v
Enable call out for the serial port where the modem is connected.
v
Set the serial port line speed.
v
Enter the modem configuration filename.
v
Set up site-specific parameters (such as phone numbers for call-in and call-out
policy).
v
To call out before restart, set Call-Out before restart to Enabled from the
Reboot/Restart Policy Setup menu.
Note: Some modems, such as IBM 7857-017, are not designed for the paging function.
Although they can be used for paging, they return an error message when they
do not get the expected response from another modem. Therefore, even though
the paging was successful, the error message causes the service processor to
retry, continuing to place pager calls for the number of retries specified in the
Call-Out policy Setup Menu. These retries result in redundant pages.
Chapter 3. Using the Service Processor
51
Summary of Contents for Intellistation POWER 9112 265
Page 1: ...Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00 IBM...
Page 2: ......
Page 3: ...Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00 IBM...
Page 12: ...x User s Guide...
Page 16: ...xiv User s Guide...
Page 18: ...xvi User s Guide...
Page 26: ...6 User s Guide...
Page 160: ...140 User s Guide...
Page 164: ...144 User s Guide...
Page 178: ...158 User s Guide...
Page 182: ...162 User s Guide...
Page 192: ...172 User s Guide...
Page 218: ...198 User s Guide...
Page 222: ...202 User s Guide...
Page 225: ......
Page 227: ...Spine information IBM Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00...