recoverable and irrecoverable error indications. The firmware uses the error signatures
in the hardware to analyze and isolate the error to a specific processor.
The processors that are deconfigured remain offline for subsequent reboots until the
faulty processor hardware is replaced.
This function allows users to manually deconfigure or re-enable a previously
deconfigured processor through the service processor menu. The user can also enable
or disable this function through the service processor.
Memory Boot-Time Deconfiguration (Memory Repeat Gard)
Memory boot-time deconfiguration allows for the removal of a memory segment or
DIMM from the system configuration at boot time. The objective is to minimize system
failures or data integrity exposure due to faulty memory hardware. The hardware
resource(s) to be removed are the ones that experienced the following failures:
v
A boot-time test failure
v
Run-time recoverable errors over the error threshold prior to the current boot phase
v
Run-time irrecoverable errors prior to the current boot phase
This function uses firmware power-on self-test (POST) to discover and isolate memory
hardware failures during boot time. It also uses the hardware error detection logic in the
memory controller to capture run-time recoverable and irrecoverable errors. The
firmware uses the error signatures in the hardware to analyze and isolate the error to
the specific memory segment or DIMM.
The memory segment or DIMM that is deconfigured remains offline during subsequent
reboots until the faulty memory hardware is replaced.
The function allows users to manually deconfigure or re-enable a previously
deconfigured memory segment/DIMM through the service processor menu. The user
can also enable or disable this function through the service processor menu.
Chapter 3. Using the Service Processor
49
Summary of Contents for Intellistation POWER 9112 265
Page 1: ...Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00 IBM...
Page 2: ......
Page 3: ...Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00 IBM...
Page 12: ...x User s Guide...
Page 16: ...xiv User s Guide...
Page 18: ...xvi User s Guide...
Page 26: ...6 User s Guide...
Page 160: ...140 User s Guide...
Page 164: ...144 User s Guide...
Page 178: ...158 User s Guide...
Page 182: ...162 User s Guide...
Page 192: ...172 User s Guide...
Page 218: ...198 User s Guide...
Page 222: ...202 User s Guide...
Page 225: ......
Page 227: ...Spine information IBM Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00...