111
Updated
28/02/01
IBM Rack Mounted Units
Description
Machine
Type or Part
Number
Size
(U)
4
Approx
Weight
(Kg)
P
o
w
er (W
a
tts
)
T
y
p
ic
a
l /
Max
(A
ll
co
rds
to
s
a
m
e
s
o
ur
ce)
Nu
mb
er
of
P
o
w
er
Su
ppl
ie
s a
n
d
Li
n
e C
o
rds
6
(b
asi
c/ma
x)
Server System Units
xSeries 200
1
8478
4
19
245/350
1/1
xSeries 220
1
8645
4
19
245/350
1/1
xSeries 330
2
8654
1
13
140/200
1/1
Netfinity 4000R
8652
1
10
105/150
1/1
xSeries 340 / Netfinity 4500R
8656
3
28
270/415
1/2
xSeries 230 / Netfinity5100
8658
5
36
250/357
1/1
xSeries 230 / Netfinity5100
w/Pwr Upgrade
5
8658
5
36
315/450
1/3
5
xSeries 240 / Netfinity5600
8664
5
36
315/450
2/3
Netfinity 6000R
8682
3
34
365/525
1/3
Netfinity 7100
8666
8
56
350/475
2/4
Netfinity 7600
8665
8
56
350/475
3/4
Netfinity 8500R
3
8681
8
73
1015/1450
3/3
Storage Units
EXP200
P/N 00N6xxx
3
41
280/350
1/2
EXP300
P/N 19K11xx
3
41
285/360
2/2
FAStT200
P/N 19K11xx
3
25
275/390
2/2
FAStT200HA
P/N 19K11xx
3
25
275/390
2/2
FC RAID Controller Unit
P/N SFCU1xx
4
34
105/160
2/2
FAStT500 Storage Server
P/N 00N69xx
4
34
140/200
2/2
FAStT EXP500 Storage Expansion Unit
P/N 00N71xx
3
28
245/350
2/2
SAN FC Switch 8-port
P/N 2109S08
1
8
-/200
1/2
SAN FC Switch 16-port
P/N 2109S16
2
13
-/200
1/2
Tape Unit/Enclosure
NetMEDIA
P/N 03K8756
3
17
130/185
2/2
DLT Tape Library
P/N 00N79xx
4
32
-/135
1/1
1. Requires 4Ux20D Tower-to-Rack Kit P/N 09N4300 to mount server unit into an EIA rack cabinet.
2. To provide adequate cooling, blank filler panel kit P/N 94G6670 should be placed on the front of any unused rack space. If non-IBM racks are
to be used, assure that both front and rear doors offer a minimum of 48% open area uniformly distributed and in line with installed servers. A
clearance of 51 to 64mm (2 to 2.5in) must be maintained between the front of the door and the system unit’s front bezel. The rear door must
maintain the same or greater clearance. Nonrack or NetBAY3 installations are not supported.
3. 8500R requires installation of extension kit P/N 36L9703 or P/N 36L9702 when installed in a Rack P/Ns 9306900/9306910 or P/N 9306200
respectively, for proper rear door clearance.
4. 1U= 1.75in= 44.45mm.
5. One power supply standard; the Hot-Swap Power Supply Upgrade Kit P/N 37L6881 allows one to three hot swap power supplies.
6. Standard Country Line Cords are supplied standard with all units. Rack Power Cord P/N 94G7448 (one for each power supply) must be
ordered optionally if connecting to a high voltage UPS or PDU.
7. BTUs = Watts x 3.41
8. General rack placement rules and other information:
- Locate heaviest components at the bottom of the rack (i.e. UPS, then servers or storage, etc.)
- Do not extend more than one component on side rails at a time.
- Maximum of three UPS (including no more than two APC 5000 UPS) per rack.
- Utilise side compartments for mounting PDU’s and console switches prior to using EIA space.
- When mounting components in a rack, consider user and service requirements.
- When selecting length of power, console and storage cables, consider extension of cable management arms and overall cable routing.
Summary of Contents for eServer xSeries
Page 20: ...19 Updated 28 02 01...
Page 28: ...27 Updated 28 02 01...
Page 36: ...35 Updated 28 02 01...
Page 44: ...43 Updated 28 02 01...
Page 58: ...57 Updated 28 02 01...
Page 66: ...65 Updated 28 02 01...
Page 92: ...91 Updated 28 02 01...
Page 96: ...95 Updated 28 02 01...
Page 116: ...115 Updated 28 02 01...
Page 120: ...119 Updated 28 02 01...