52
Updated
28/02/01
To access IBM information specific to your country via the World Wide Web, use address: http://www.ibm.com/pc
xSeries 340 / Netfinity 4500R Internal SCSI Cabling
The xSeries 340 and Netfinity 4500R contain a DASD backplane supporting three hot-swap, SCA-2 compliant drive bays. The backplane is connected to one of the internal
connectors of the integrated Ultra160 SCSI controller through a 16-bit LVD SCSI cable. A single-drop 16-bit SCSI cable is included with the server for attachment from the second
internal Ultra160 connector to a removable media bay device. If an LVD attachment is required or more than one media bay device is required, a terminated two-drop 16-bit LVD
SCSI cable available in the Netfinity Media Bay Conversion Kit P/N 10K2340 must be ordered. No external SCSI port is included.
If optional Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050 is installed in the removable media bays, four cabling options are possible. Included with this option is
a 16-bit LVD SCSI cable, identical to the one used for attachment of the standard hot-swap backplane, which can be used to attach the optional 3-Pack Ultra160 Hot-Swap backplane
directly to the second onboard SCSI connector or that of an optional RAID adapter. Alternatively, a repeater card and cable are included which may be used to link the standard hot-
swap backplane and optional hot-swap backplane together while utilising the standard SCSI cable for attachment of the repeater card to one of the onboard SCSI connectors or that
of an optional RAID adapter.
Bay
Form Factor
Height
Front
Access
Usage
Part
Number
Description
RPM
Height
Bays
Supported
2
Max.
Qty.
-
89 mm
(3.5”)
-
Yes
Diskette
Ultra160 Hard Disk Drives (HDD)
-
133 mm (5.25”)
-
Yes
IDE CD-
ROM
37L7201
9.1 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
1...6
6
1
1...3
HS
SL
1
Yes
Open
37L7202
18.2 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
1...6
6
1
A, B
133 mm
(5.25”)
HH
2
Yes
Open
37L7203
36.4 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
1...6
6
1
4...6
3
HS
SL
1
Yes
Open
37L7204
9.1 GB 10K-4 Ultra160 SCSI Hot-Swap
HDD
10,000
SL
1...6
6
1
1. Half-High devices are NOT supported.
2 Two half-high (HH) bays can be combined to support a single full-high (FH)
device. By installing Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit (P/N
33L5050), bays A and B are transformed into three SL hot-swap
bays 4...6.
3. To enable bays 4...6, optional Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit
(P/N 33L5050) is required.
37L7205
18.2 GB 10K-4 Ultra160 SCSI Hot-Swap
HDD
10,000
SL
1...6
6
1
37L7206
36.4 GB 10K-4 Ultra160 SCSI Hot-Swap
HDD
10,000
SL
1...6
6
1
19K0655
9.1 GB 15K-rpm Ultra160 SCSI Hot-Swap
HDD
15000
SL
1...6
6
1
19K0656
18.2 GB 15K-rpm Ultra160 SCSI Hot-
Swap HDD
15000
SL
1...6
6
1
Associated Options
33L5050
Netfinity 3-Pack Ultra160 Hot-Swap
Expansion Kit
1, 2
-
3 x SL
4...6
-
External Storage Expansion Units
3
Form Factor
19K11xx
9
EXP300 Storage Expansion Unit
4, 8
Rack (3U)
19K11xx
10
FAStT 200 Storage Server
5, 6, 8
Rack (3U)
19K11xx
11
FAStT 200 HA Storage Server
5, 8
Rack (3U)
19K1121
FAStT 200 Redundant RAID Controller
6
-
00N71xx
12
FAStT EXP500 Storage Expansion Unit
7, 8
Rack (3U)
94G7448
Rack Power Cable Type C12 (3.7m)
8
-
1. Netfinity 4500R ships with Bays 1...3 enabled. To enable installation of greater than three HDDS requires Netfinity 3-
Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050.
2. Netfinity 3-Pack Ultra160 Hot-Swap Expansion Kit P/N 33L5050 includes a hot-swap backplane and associated
components for two cabling options. The backplane may be cabled directly to the second integrated SCSI channel or be
supported by the same SCSI channel as the standard backplane through the use of an included repeater card.
3. Select an optional SCSI controller and then refer to Appendix D: Cables-Storage Units-Controllers to confirm the
controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other
expansion unit options, see the specific expansion unit section.
4. The EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies, each with a
standard country power cord..
5. The FAStT200 Storage Server and HA Storage Server each include two hot-swap, 350 W auto-ranging redundant
power supplies each with it’s own standard country power cord.
6. Can be upgraded to a FAStT200 HA Storage Server through the addition of a FAStT200 Redundant RAID Controller
P/N 19K1121.
7. The FAStT EXP500 Storage Expansion Unit (P/N 00N71xx) includes dual hot-swap 350W power supplies, each with
it’s own standard country power cord.
8. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or
PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of
power supplies.
9.Where ‘xx’ represents a specific country code as follows: 51=US/English, 52=European/English, 56=Danish/English,
57=Israel/English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/
Publication Country Kits are included as indicated.
10. Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish,
27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English, 31=South Africa/English, 32=Switzerland/
English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated
11. Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish,
41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English, 45=South Africa/English, 46=Switzerland/
English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as
indicated.
12. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,
42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/
Language Line Cords/Publications are included as indicated.
Diskette
CD-ROM
RM A
RM B
HS 4
HS 5
HS 6
Removable Media
(RM)
1
2
3
Hot-Swap
(HS)
Summary of Contents for eServer xSeries
Page 20: ...19 Updated 28 02 01...
Page 28: ...27 Updated 28 02 01...
Page 36: ...35 Updated 28 02 01...
Page 44: ...43 Updated 28 02 01...
Page 58: ...57 Updated 28 02 01...
Page 66: ...65 Updated 28 02 01...
Page 92: ...91 Updated 28 02 01...
Page 96: ...95 Updated 28 02 01...
Page 116: ...115 Updated 28 02 01...
Page 120: ...119 Updated 28 02 01...