85
Updated
28/02/01
Netfinity 8500R Internal Hard Disk Drive (HDD) and External Storage Configurator
Total
Internal
Storage
1
7200 RPM Ultra160 SCSI HDDs
10,000 RPM Ultra160 SCSI HDDs
15,000 RPM Ultra160 SCSI
HDDs
9.1 GB
(P/N 37L7201)
2
18.2 GB
(P/N 37L7202)
2
36.4 GB
(P/N 37L7203)
2
9.1 GB
(P/N 37L7204)
2
18.2 GB
(P/N 37L7205)
2
36.4 GB
(P/N 37L7206)
2
9.1 GB
(P/N 19K0655)
2
18.2 GB
(P/N 19K0656)
2
0 GB
0GB Standard on Base Models
0GB Standard on Base Models
0GB Standard on Base Models
9.1 GB
1
-
-
1
-
-
1
-
18.2 GB
2 or
1
-
2 or
1
-
2 or
1
36.4 GB
-
2 or
1
-
2 or
1
-
2
72.8 GB
(max)
-
-
2
-
-
2
-
-
This table does not represent all possible hard disk drive (HDD) configurations.
1. Select a total storage row and then select the quantity of HDDs from a column corresponding to the HDD of choice. Total Internal Storage listed is
0.2 GB unless otherwise noted.
2. Netfinity 8500R contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.
Bay
Form
Factor
Height
Front
Access
Usage
Part
Number
Description
RPM
Height
Bays
Supported
Max
Qty.
-
133 mm
(5.25”)
HH
Yes
IDE CD-ROM
Ultra160 Hard Disk Drives (HDD)
1
-
89 mm
(3.5”)
SL
Yes
Diskette
37L7201
9.1 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
1, 2
2
1...2
HS
HH
Yes
Open
37L7202
18.2 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
1, 2
2
NB3E
1
19” Rack
3U
Yes
Open
37L7203
36.4 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
1, 2
2
1. A total of three optional 3U NetBAY3Es can be stacked beneath a Netfinity
8500R which has Netfinity 8Ux28D Rack-to-Tower Kit (P/N 28L4705)
installed. See IBM Netfinity NetBAY3x Stackable Enclosure section for
supported devices.
37L7204
9.1 GB 10K-4 Ultra160 SCSI Hot-Swap
HDD
10,000
SL
1, 2
2
37L7205
18.2 GB 10K-4 Ultra160 SCSI Hot-Swap
HDD
10,000
SL
1, 2
2
37L7206
36.4 GB 10-K Ultra160 SCSI Hot-Swap
HDD
10,000
SL
1, 2
2
19K0655
9.1 GB 15K-rpm Ultra160 SCSI Hot-Swap
HDD
15,000
SL
1, 2
2
19K0656
18.2 GB 15K-rpm Ultra160 SCSI Hot-Swap
HDD
15,000
SL
1, 2
2
External Storage Expansion Units
2
Form Factor
19K11xx
8
EXP300 Storage Expansion Unit
3, 7
Rack (3U)
09N7296
EXP300 Rack-to-Tower Conversion Kit
-
19K11xx
9
FAStT 200 Storage Server
4, 5, 7
Rack (3U)
19K11xx
10
FAStT 200 HA Storage Server
4, 7
Rack (3U)
19K1121
FAStT 200 Redundant RAID Controller
5
-
00N71xx
11
FAStT EXP500 Storage Expansion Unit
6, 7
Rack (3U)
94G7448
Rack Power Cable Type C12 (3.7m, 12 ft.)
7
-
1. Netfinity 8500R contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.
2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to Appendix D: Cables-
Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a
supported cable. For HDD or other expansion unit options, see the specific expansion unit section.
3. The EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies, each with it’s
own standard country power cord. To convert an EXP300 to a tower form factor, EXP300 Rack-to-Tower Conversion Kit
P/N 09N7296 is required.
4. The FAStT200 Storage Server and HA Storage Server each include two hot-swap, 350 W auto-ranging redundant power
supplies each with it’s own standard country power cord.
5. Can be upgraded to a FAStT200 HA Storage Server through the addition of a FAStT200 Redundant RAID Controller P/
N 19K1121.
6. The FAStT EXP500 Storage Expansion Unit includes dual hot-swap 350 W power supplies, each with it’s own standard
country power cord.
7. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or
PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of
power supplies.
8. Where ‘xx’ represents a specific country code as follows: 51=US/English, 52=European/English, 56=Danish/English,
57=Israel/English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/
Publication Country Kits are included as indicated.
9. Where ‘xx’ represents a country specific code as follows:- 23=US/English, 24=Euro/English, 25=Euro/Spanish,
27=Euro/German, 28=Denmark/English, 29=Israel/English, 30=Italy/English, 31=South Africa/English, 32=Switzerland/
English, 34=Switzerland/German, 36=UK/English. Country/Language - Line Cords/Publications are included as indicated
10. Where ‘xx’ represents a country specific code as follows:- 37=US/English, 38=Euro/English, 39=Euro/Spanish,
41=Euro/German, 42=Denmark/English, 43=Israel/English, 44=Italy/English, 45=South Africa/English, 46=Switzerland/
English, 48=Switzerland/German, 50=UK/English. Country/Language - Line Cords/Publications are included as indicated.
11. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,
42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/
Language Line Cords/Publications are included as indicated.
Hot-Swap (HS)
Bay 1
Bay 2
Diskette
CD-ROM
Netfinity NetBAY3E (NB3E)
(Optional)
(Requires Rack to
Tower Kit)
Summary of Contents for eServer xSeries
Page 20: ...19 Updated 28 02 01...
Page 28: ...27 Updated 28 02 01...
Page 36: ...35 Updated 28 02 01...
Page 44: ...43 Updated 28 02 01...
Page 58: ...57 Updated 28 02 01...
Page 66: ...65 Updated 28 02 01...
Page 92: ...91 Updated 28 02 01...
Page 96: ...95 Updated 28 02 01...
Page 116: ...115 Updated 28 02 01...
Page 120: ...119 Updated 28 02 01...