Service
request
number
SRN
source
Description
FRU/action
A01-02x
G
CPU
internal
cache
or
cache
controller
error.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A01-05x
G
System
bus
time-out
error.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A01-06x
G
Time-out
error
waiting
for
I/O.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A01-07x
G
System
bus
parity
error.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A01-08x
G
System
bus
protocol/transfer
error.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A02-00x
G
Error
log
analysis
indicates
an
error
detected
by
the
memory
controller,
but
the
failure
could
not
be
isolated.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A02-01x
G
Uncorrectable
Memory
Error.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A02-03x
G
Correctable
error
threshold
exceeded.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
122
BladeCenter
JS20
Type
8842:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for BladeCenter JS20
Page 1: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 22: ...12 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 30: ...20 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 68: ...58 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 183: ...Appendix B Safety information 173...
Page 184: ...174 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 185: ...Appendix B Safety information 175...
Page 186: ...176 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 187: ...Appendix B Safety information 177...
Page 188: ...178 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 189: ...Appendix B Safety information 179...
Page 190: ...180 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 200: ...190 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 201: ...Appendix B Safety information 191...
Page 202: ...192 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 203: ...Appendix B Safety information 193...
Page 212: ...202 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 217: ......
Page 218: ...Part Number 90P3485 Printed in USA 1P P N 90P3485...