Service
request
number
SRN
source
Description
FRU/action
A1D-21x
G
A
non-critical
error
has
been
detected,
a
service
processor
detected
error
with
time-of-day
clock
backup
battery.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A1D-23x
G
A
non-critical
error
has
been
detected:
Loss
of
heart
beat
from
Service
Processor.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A1D-24x
G
A
non-critical
error
has
been
detected,
a
service
processor
detected
a
surveillance
time-out.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A1D-29x
G
A
non-critical
error
has
been
detected,
a
service
process
error
accessing
power
control
network.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A1D-30x
G
A
non-critical
error
has
been
detected:
Non-supported
hardware.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A1D-31x
G
A
non-critical
error
has
been
detected:
Error
detected
while
handling
an
attention/interrupt
from
the
system
hardware.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A1D-34x
G
A
non-critical
error
has
been
detected:
Wire
Test
Error.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
A1D-35x
G
A
non-critical
error
has
been
detected:
Mainstore
or
Cache
IPL
Diagnostic
Error.
1.
Check
the
BladeCenter
management
module
event
log;
if
an
error
was
recorded
by
the
system
or
if
a
checkpoint
code
is
displayed
on
the
console,
see
Chapter
10,
“Symptom-to-FRU
index,”
on
page
93.
2.
If
no
entry
is
found,
replace
the
system
board.
140
BladeCenter
JS20
Type
8842:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for BladeCenter JS20
Page 1: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 22: ...12 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 30: ...20 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 68: ...58 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 183: ...Appendix B Safety information 173...
Page 184: ...174 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 185: ...Appendix B Safety information 175...
Page 186: ...176 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 187: ...Appendix B Safety information 177...
Page 188: ...178 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 189: ...Appendix B Safety information 179...
Page 190: ...180 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 200: ...190 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 201: ...Appendix B Safety information 191...
Page 202: ...192 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 203: ...Appendix B Safety information 193...
Page 212: ...202 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 217: ......
Page 218: ...Part Number 90P3485 Printed in USA 1P P N 90P3485...