Service
request
number
SRN
source
Failing
Function
Code
Description
and
action
652-66B
G
2CC
A
non-critical
error
has
been
detected:
correctable
error
threshold
exceeded.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-731
G
2C8
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
address
parity
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-732
G
2C8
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
data
parity
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-733
G
2C8
292
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
address
parity
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-734
G
2C8
292
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
data
parity
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-735
G
2D2
292
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
time-out
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-736
G
2D2
292
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
time-out
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-770
G
2C8
292
A
non-critical
error
has
been
detected:
intermediate
system
bus
address
parity
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-771
G
2C8
292
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
data
parity
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-772
G
2D2
292
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
time-out
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-773
G
227
A
non-critical
error
has
been
detected:
intermediate
or
system
bus
data
parity
error.
Action:
Schedule
deferred
maintenance.
Use
Chapter
4,
“Problem
determination
procedures
for
AIX
and
Linux,”
on
page
21.
652-88x
G
The
CEC
or
SPCN
reported
a
non-critical
error.
Action:
Schedule
deferred
maintenance.
Refer
to
the
entry
MAP
in
this
system
unit’s
system
service
guide,
with
the
8-digit
error
and
location
codes,
for
the
necessary
repair
action.
If
the
8-digit
error
and
location
codes
were
NOT
reported,
then
run
diagnostics
in
problem
determination
mode
and
record
and
report
the
8-digit
error
and
location
codes
for
this
SRN.
652-89x
G
The
CEC
or
SPCN
reported
a
non-critical
error.
Action:
Schedule
deferred
maintenance.
Refer
to
the
entry
MAP
in
this
system
unit’s
system
service
guide,
with
the
8-digit
error
and
location
codes,
for
the
necessary
repair
action.
If
the
8-digit
error
and
location
codes
were
NOT
reported,
then
run
diagnostics
in
problem
determination
mode
and
record
and
report
the
8-digit
error
and
location
codes
for
this
SRN.
814-112
D
814
The
NVRAM
test
failed.
814-113
D
221
The
VPD
test
failed.
814-114
D
814
I/O
Card
NVRAM
test
failed.
815-100
D
815
The
floating-point
processor
test
failed.
118
BladeCenter
JS20
Type
8842:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for BladeCenter JS20
Page 1: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 22: ...12 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 30: ...20 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 68: ...58 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 183: ...Appendix B Safety information 173...
Page 184: ...174 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 185: ...Appendix B Safety information 175...
Page 186: ...176 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 187: ...Appendix B Safety information 177...
Page 188: ...178 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 189: ...Appendix B Safety information 179...
Page 190: ...180 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 200: ...190 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 201: ...Appendix B Safety information 191...
Page 202: ...192 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 203: ...Appendix B Safety information 193...
Page 212: ...202 BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide...
Page 217: ......
Page 218: ...Part Number 90P3485 Printed in USA 1P P N 90P3485...