v
To automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller
(QAUTORMT) system value.
v
To manually connect the AS/400 to a 5494 controller:
– See “Example: Connecting AS/400 to a 5494 controller connected by Ethernet” for an example of
connecting AS/400 to a 5494 controller by Ethernet.
– Use the following table to configure the AS/400 to a 5494 controller that is connected by Ethernet.
For more information about configuring the 5494, see these books:
v
IBM 5494 Remote Control Unit Planning Guide
, GA27-3936
v
IBM 5494 Remote Control Unit User’s Guide
, GA27-3852
AS/400
Prompt
AS/400
Parameter
5494
AS/400
Value
5494 Value
Notes
Field
Subfield
Local
adapter
address
ADPTADR
H1
5
-
-
Values specified in the AS/400 line
description (CRTLINTRN command)
and for the 5494 Remote Controller
Unit must match.
LAN remote
adapter
address
ADPTADR
15
-
-
-
Values specified for the AS/400
CRTCTLAPPC command and for
the 5494 Remote Control Unit must
match.
Local
location
name
LCLLOCNAME
H1
1
-
-
Values specified for the AS/400
CRTCTLRWS command and for the
5494 Remote Control Unit must
match. This will probably match
LCLLOCNAME in the network
attributes. This value will probably
match the LCLLOCNAME in the
network attributes.
Remote
control
point name
RMTCPNAME
13
-
-
-
Values specified for the AS/400
CRTCTLAPPC command and for
the 5494 Remote Control Unit must
match.
Remote
network
identifier
RMTNETID
11
3
-
-
Values specified for the AS/400
CRTCTLAPPC and CRTCTLRWS
commands and for the 5494
Remote Control Unit must match.
This will probably match LCLNETID
in the network attributes and H1:2.
Remote
location
name
RMTLOCNAME
12
-
-
-
Values specified for the AS/400
CRTCTLRWS command and for the
5494 Remote Control Unit must
match.
Example: Connecting AS/400 to a 5494 controller connected by Ethernet
Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.
Example:
AS/400 to 5494 controller that is connected by Ethernet
The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you
use Ethernet.
Chapter 7. Communicating with remote workstation controllers
45
Summary of Contents for AS/400
Page 1: ...iSeries Networking iSeries Communications Management ERserver...
Page 2: ......
Page 3: ...iSeries Networking iSeries Communications Management ERserver...
Page 8: ...2 Version 5...
Page 10: ...4 Version 5...
Page 12: ...6 Version 5...
Page 22: ...For more information about creating subsystems see the Work Management book 16 Version 5...
Page 26: ...20 Version 5...
Page 34: ...Example 3 AS 400 system for DLUR support with the host system 28 Version 5...
Page 36: ...30 Version 5...
Page 46: ...40 Version 5...
Page 57: ...Chapter 7 Communicating with remote workstation controllers 51...
Page 63: ...Chapter 7 Communicating with remote workstation controllers 57...
Page 82: ...Example 2 AS 400 to 4690 PEER connection over token ring network 76 Version 5...
Page 83: ...Chapter 7 Communicating with remote workstation controllers 77...
Page 84: ...78 Version 5...
Page 102: ...96 Version 5...
Page 103: ......
Page 104: ...Printed in U S A...