AS/400
Prompt
AS/400
Parameter
3274
Sequence
Number
Notes
Connection
number
CNNNBR
411
3274 DTE Address
For X.25 SVCs, the connection number specified on the
CRTCTLRWS command and in sequence number 411 must
match.
Exchange
identifier
EXCHID
215
Physical Unit Identification
For switched connections, the 5-digit hexadecimal value specified
for sequence number 215 must match the last 5 digits of the
exchange identifier specified on the CRTCTLRWS command.
X.25 link
protocol
LINKPCL
403
Logical Link Control
For X.25 connections, values specified must match. Specify
LINKPCL(*QLLC) on the CRTCTLRWS command; specify
1
(QLLC) for sequence number 403.
Link type
LINKTYPE
331
BSC/SDLC/X.25 Protocol
Values specified on the CRTCTLRWS command and in
sequence number 331 must match as follows:
v
If LINKTYPE(*SDLC), 331 = 1
v
If LINKTYPE(*X25), 331 = 2
Local network
address
NETADR
410
Host DTE Address (HNAD)
For X.25 SVCs, the network address specified on the
CRTLINX25 command and in sequence number 410 must match.
Modem data
rate select
MODEMRATE
318
Full- or Half-Speed Transmission
The values specified for the MODEMRATE parameter on the
CRTLINSDLC and CRTLINX25 commands must match sequence
number 318 as follows:
v
If MODEMRATE(*FULL), 318 = 0
v
If MODEMRATE(*HALF), 318 = 1
NRZI data
encoding
NRZI
313
NRZ or NRZI Encoding
For SDLC lines only, the values specified must match as follows:
v
If NRZI(*NO), 313 = 0
v
If NRZI(*YES), 313 = 1
Short-hold
mode
SHM
362
X.21 Switched Options
If SHM(*YES) is specified on the CRTCTLRWS command, digit 7
or 8 of question 362 must be set to 1. (For example, xxxxxx10
indicates that the DCE is supported for direct calls.)
Station address STNADR
302
Control Unit Address
Value specified for item 302 must match that specified on the
CRTCTLRWS command.
Example: Connecting an AS/400 to a 3174 control unit
Configuration parameters must be coordinated when you connect an AS/400 system to a 3174 controller.
Chapter 7. Communicating with remote workstation controllers
61
Summary of Contents for AS/400
Page 1: ...iSeries Networking iSeries Communications Management ERserver...
Page 2: ......
Page 3: ...iSeries Networking iSeries Communications Management ERserver...
Page 8: ...2 Version 5...
Page 10: ...4 Version 5...
Page 12: ...6 Version 5...
Page 22: ...For more information about creating subsystems see the Work Management book 16 Version 5...
Page 26: ...20 Version 5...
Page 34: ...Example 3 AS 400 system for DLUR support with the host system 28 Version 5...
Page 36: ...30 Version 5...
Page 46: ...40 Version 5...
Page 57: ...Chapter 7 Communicating with remote workstation controllers 51...
Page 63: ...Chapter 7 Communicating with remote workstation controllers 57...
Page 82: ...Example 2 AS 400 to 4690 PEER connection over token ring network 76 Version 5...
Page 83: ...Chapter 7 Communicating with remote workstation controllers 77...
Page 84: ...78 Version 5...
Page 102: ...96 Version 5...
Page 103: ......
Page 104: ...Printed in U S A...