To configure an AS/400 to a retail controller, see the following.
v
“Matching AS/400 parameters for 3651 retail controllers”
v
“Matching AS/400 parameters for 3684 retail controllers” on page 70
v
“Matching AS/400 parameters for 4680/4690 LINE parameter” on page 72
v
“Matching AS/400 parameters for 4680/4690 LINK parameter” on page 73
v
“Matching AS/400 parameters for 4684 retail controllers” on page 74
Matching AS/400 parameters for 3651 retail controllers
You must coordinate several parameter values for retail communications. These values are specified for
the AS/400 system and the 3651 retail controller. The following table lists those AS/400 parameters that
must match values for the 3651 retail controllers.
Before you match parameters for 3651 retail controllers, you need to match AS/400 controller, device, and
line descriptions parameters with the host system.
AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified
are included in the rightmost column of the table.
For more information about configuring the 3651 controller, see the
IBM Programmable Store System
Language and Host Services: Macro Reference
To configure the AS/400 to a 3651 retail controller, use the following table.
AS/400 Prompt
AS/400
Parameter
3651 Definition
Statement
3651 Parameter
Connection type
CNN
QFHOST
SDLCLIN
Value specified for the AS/400 CNN parameter on the
CRTLINSDLC command must match the values
specified for bits 2 and 3 of the 3651 SDLCLIN
parameter.
Duplex
DUPLEX
QFHOST
SDLCLIN
Value specified for the AS/400 DUPLEX parameter on
the CRTLINSDLC command must match the value
specified for bit 6 of the 3651 SDLCLIN parameter.
Exchange identifier
EXCHID
QFHOST
SENDID
3651 SENDID parameter must match the last 5 digits of
the EXCHID parameter specified on the AS/400
CRTLINSDLC command. (This parameter is used only
for switched line communications.)
RECVID
3651 RECVID parameter must match the last 5 digits of
the EXCHID parameter specified on the AS/400
CRTCTLRTL command.
Modem data rate
MODEMRATE
QFHOST
SDLCLIN
Value specified for the AS/400 MODEMRATE parameter
on the CRTLINSDLC command must match the value
specified for bit 5 of the 3651 SDLCLIN parameter.
NRZI data encoding
NRZI
QFHOST
SDLCLIN
Value specified for the AS/400 NRZI parameter on the
CRTLINSDLC command must match the value specified
for bit 1 of the 3651 SDLCLIN parameter.
68
Version 5
Summary of Contents for AS/400
Page 1: ...iSeries Networking iSeries Communications Management ERserver...
Page 2: ......
Page 3: ...iSeries Networking iSeries Communications Management ERserver...
Page 8: ...2 Version 5...
Page 10: ...4 Version 5...
Page 12: ...6 Version 5...
Page 22: ...For more information about creating subsystems see the Work Management book 16 Version 5...
Page 26: ...20 Version 5...
Page 34: ...Example 3 AS 400 system for DLUR support with the host system 28 Version 5...
Page 36: ...30 Version 5...
Page 46: ...40 Version 5...
Page 57: ...Chapter 7 Communicating with remote workstation controllers 51...
Page 63: ...Chapter 7 Communicating with remote workstation controllers 57...
Page 82: ...Example 2 AS 400 to 4690 PEER connection over token ring network 76 Version 5...
Page 83: ...Chapter 7 Communicating with remote workstation controllers 77...
Page 84: ...78 Version 5...
Page 102: ...96 Version 5...
Page 103: ......
Page 104: ...Printed in U S A...