Chapter 7. Communicating with remote workstation
controllers
You can configure the AS/400 system to communicate with another AS/400 system, a non-AS/400 system,
or a remote controller. This configuration requires the coordination of configuration parameters and values.
To configure your AS/400 to communicate with remote workstation controllers, see the following:
v
“Matching AS/400 parameters for 5494 controllers”
v
“Matching AS/400 parameters for 3x74 controller” on page 58
v
“Matching AS/400 parameters for finance controllers” on page 62
v
“Matching AS/400 parameters for retail controllers” on page 67
Matching AS/400 parameters for 5494 controllers
You must coordinate the configuration parameters and values to configure the AS/400 system to
communicate with a 5494 controller. You can coordinate these values automatically or manually. Pick one
of the ways:
v
To automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller
(QAUTORMT) system value.
v
To manually connect the AS/400 to a 5494, you can use the following examples and the tables.
The list contains only those configuration prompts and parameters that require coordination on both
AS/400 and the 5494 controller. In addition, some of the parameters that are listed may not apply to
your particular configuration.
– “Matching AS/400 parameters for a 5494 connected by token-ring”
– “Matching AS/400 parameters for a 5494 connected by Ethernet” on page 44
– “Matching AS/400 parameters for a 5494 connected by frame relay” on page 46
– “Matching AS/400 parameters for a 5494 connected by SDLC” on page 48
– “Matching AS/400 parameters for a 5494 connected by X.21” on page 52
– “Matching AS/400 parameters for a 5494 connected by X.25” on page 54
For more information about configuring the 5494, see these books:
v
IBM 5494 Remote Control Unit Planning Guide
, GA27-3936
v
IBM 5494 Remote Control Unit User’s Guide
, GA27-3852
v
Remote Work Station Support
.
Matching AS/400 parameters for a 5494 connected by token-ring
You must coordinate communications configuration parameters between AS/400 and the 5494 controller
that is connected by token-ring. You can coordinate these values automatically or manually. Pick one of
these ways:
v
To automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller
(QAUTORMT) system value.
v
To manually connect the AS/400 to a 5494:
– See “Example: Connecting AS/400 to a 5494 controller connected by token-ring” on page 43 for an
example of connecting AS/400 to a 5494 controller by token-ring.
– Use the following table to configure the AS/400 to a 5494 controller that is connected by token-ring.
The following table gives a description of the parameters . The related fields and subfields from the
5494 configuration display, the AS/400 configuration value, and the matching 5494 value to enter are
shown.
For more information about configuring the 5494, see these books:
v
IBM 5494 Remote Control Unit Planning Guide
, GA27-3936,
v
IBM 5494 Remote Control Unit User’s Guide
, GA27-3852
© Copyright IBM Corp. 1998, 2001
41
Summary of Contents for AS/400
Page 1: ...iSeries Networking iSeries Communications Management ERserver...
Page 2: ......
Page 3: ...iSeries Networking iSeries Communications Management ERserver...
Page 8: ...2 Version 5...
Page 10: ...4 Version 5...
Page 12: ...6 Version 5...
Page 22: ...For more information about creating subsystems see the Work Management book 16 Version 5...
Page 26: ...20 Version 5...
Page 34: ...Example 3 AS 400 system for DLUR support with the host system 28 Version 5...
Page 36: ...30 Version 5...
Page 46: ...40 Version 5...
Page 57: ...Chapter 7 Communicating with remote workstation controllers 51...
Page 63: ...Chapter 7 Communicating with remote workstation controllers 57...
Page 82: ...Example 2 AS 400 to 4690 PEER connection over token ring network 76 Version 5...
Page 83: ...Chapter 7 Communicating with remote workstation controllers 77...
Page 84: ...78 Version 5...
Page 102: ...96 Version 5...
Page 103: ......
Page 104: ...Printed in U S A...