Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Lotus Foundations Appliance Type 9234,” on page 19 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code
Description
Action
3-3-3
No operational memory in system.
1. Make sure that the system board contains
the correct number and type of DIMMs;
install or reseat the DIMMs; then, restart the
server.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only) System
board
No-beep symptoms
The following table describes situations in which no beep code sounds when POST
is completed.
Table 4. No-beep code symptoms
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Lotus Foundations Appliance Type 9234,” on page 19 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
No-beep symptom
Description
Action
No beeps occur, and the server
operates correctly.
1. (Trained service technician only)
Reseat the front information panel
LED cable.
2. (Trained service technician only)
Replace the front information
panel LED assembly.
No beeps occur, and there is no
video.
See “Solving undetermined problems”
on page 119.
Chapter 5. Diagnostics
81
Summary of Contents for 9234CNU - Lotus Foundations Server
Page 1: ...Lotus Foundations Appliance Type 9234 CNU and 9234 DNU Problem Determination and Service Guide...
Page 2: ......
Page 3: ...Lotus Foundations Appliance Type 9234 CNU and 9234 DNU Problem Determination and Service Guide...
Page 15: ...1 2 Safety xiii...
Page 149: ...Index Copyright IBM Corp 2008 131...
Page 151: ......
Page 152: ...Part Number 44W2553 Printed in USA 1P P N 44W2553...