6. Install the fan sink:
a. Make sure that the fan-sink retention lever is in the fully open position.
Important:
Be careful when you handle the microprocessor and fan sink.
Do not contaminate the thermal material between them.
Retention module
Fan sink
Retention lever
b. Slide the bottom edge of the fan sink under the lower flange of the
retention module; then, place the top of the fan sink onto the top of the
retention module.
c. Close the fan-sink retention lever and lock it securely in place.
d. Reconnect the fan-sink cable to the system board (see “System-board
internal connectors” on page 8 for the location of the fan-sink connector).
7. Reconnect any cables that you disconnected during the removal of the old
microprocessor.
8. Install the side cover (see “Installing the side cover” on page 31).
9. Lock the side cover if you unlocked it during removal.
10. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Thermal grease
The thermal grease must be replaced whenever the fan sink has been removed
from the top of the microprocessor and is going to be reused or when debris is
found in the grease.
When you are installing the fan sink on the same microprocessor that is was
removed from, make sure that:
v
The thermal grease on the fan sink and microprocessor is not contaminated.
v
Additional thermal grease is not added to the existing thermal grease on the fan
sink and microprocessor.
68
Lotus Foundations Appliance, Type 9234 CNU and 9234 DNU: Problem Determination and Service Guide
Summary of Contents for 9234CNU - Lotus Foundations Server
Page 1: ...Lotus Foundations Appliance Type 9234 CNU and 9234 DNU Problem Determination and Service Guide...
Page 2: ......
Page 3: ...Lotus Foundations Appliance Type 9234 CNU and 9234 DNU Problem Determination and Service Guide...
Page 15: ...1 2 Safety xiii...
Page 149: ...Index Copyright IBM Corp 2008 131...
Page 151: ......
Page 152: ...Part Number 44W2553 Printed in USA 1P P N 44W2553...