Microprocessor problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Lotus Foundations Appliance Type 9234,” on page 19 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
The server emits a continuous
beep during POST, indicating
that the startup (boot)
microprocessor is not working
correctly.
1. Make sure that the microprocessor is supported on this server.
2. (Trained service technician only) Reseat the microprocessor.
3. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. (Trained service technician only) Microprocessor
b. (Trained service technician only) System board
Monitor or video problems
Some IBM monitors have their own self-tests. If you suspect a problem with your
monitor, see the documentation that comes with the monitor for instructions for
testing and adjusting the monitor.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Lotus Foundations Appliance Type 9234,” on page 19 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
Testing the monitor
1. Make sure that the monitor cables are firmly connected.
2. Try using a different monitor on the server, or try using the monitor that is being
tested on a different server.
3. Run the diagnostic programs. If the monitor passes the diagnostic programs,
the problem might be a video device driver.
4. Reseat the Remote Supervisor Adapter II SlimLine (if one is installed).
5. Replace the Remote Supervisor Adapter II SlimLine.
6. (Trained service technician only) Replace the system board.
98
Lotus Foundations Appliance, Type 9234 CNU and 9234 DNU: Problem Determination and Service Guide
Summary of Contents for 9234CNU - Lotus Foundations Server
Page 1: ...Lotus Foundations Appliance Type 9234 CNU and 9234 DNU Problem Determination and Service Guide...
Page 2: ......
Page 3: ...Lotus Foundations Appliance Type 9234 CNU and 9234 DNU Problem Determination and Service Guide...
Page 15: ...1 2 Safety xiii...
Page 149: ...Index Copyright IBM Corp 2008 131...
Page 151: ......
Page 152: ...Part Number 44W2553 Printed in USA 1P P N 44W2553...