If you have just added new software or a new option and your server is not
working, complete the following steps before using the error symptom charts:
1. Remove the software or device that you just added.
2. Run the diagnostic tests to determine if your server is running correctly.
3. Reinstall the new software or new device.
In the following table, if the entry in the FRU/action column is a suggested action,
perform that action; if it is the name of a component, reseat the component and
replace it if necessary. The most likely cause of the symptom is listed first.
Error Symptom
FRU/Action
CD is not working properly.
1. Clean the CD.
2. Run CD-ROM diagnostics.
3. CD-ROM Drive.
CD-ROM drive tray is not working.
(The
server must be powered-on)
1. Insert the end of a paper clip into the manual tray-release opening.
2. Run CD-ROM diagnostics.
3. CD-ROM Drive.
CD-ROM drive is not recognized
.
1. Run Configuration/Setup, enable primary IDE channel.
2. Check cables and jumpers.
3. Check for correct device driver.
4. Run CD-ROM diagnostics.
5. CD-ROM Drive.
6. System Board.
Power switch does not work and reset
button does work.
1. Reseat connector.
2. Switch Card.
3. System Board.
Diskette drive in-use light stays on, or
the system bypasses the diskette drive,
or the diskette drive does not work
1. If there is a diskette in the drive, verify that:
a. The diskette drive is enabled in the Configuration/Setup utility
program.
b. The diskette is good and not damaged. (Try another diskette if
you have one.)
c. The diskette is inserted correctly in the drive.
d. The diskette contains the necessary files to start the server.
e. The software program is OK.
f. Cable is installed correctly (proper orientation).
2. Run Diskette Drive Diagnostics.
3. Cable.
4. Diskette Drive.
5. System Board.
Monitor problems (general).
Some IBM
monitors have their own self-tests. If you
suspect a problem with the monitor, refer to
the information that comes with the monitor
for adjusting and testing instructions.
1. Monitor.
2. Run Video Diagnostics. If diagnostics pass, the problem may be a
video driver.
3. Display Adapter / System Board.
No video
1. Make sure correct machine is selected.
2. Make sure all cables are locked down.
Drives not recognized by the Fixed Disk
diagnostic.
(e.g. of 6 drives, the Fixed Disk
test only shows 3)
Remove the first drive that doesn’t show up and rerun the Fixed Disk
diagnostic. If the remaining drives then show up, replace the drive you
removed.
Chapter 6. Symptom-to-FRU index
109
Summary of Contents for 8647 - Eserver xSeries 225
Page 1: ...IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 16: ...6 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 28: ...18 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 42: ...32 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 112: ...102 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 151: ...Appendix B Related service information 141...
Page 152: ...142 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 153: ...23 50 110 50 110 Appendix B Related service information 143...
Page 154: ...144 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 155: ...Appendix B Related service information 145...
Page 166: ...156 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 167: ...Appendix B Related service information 157...
Page 169: ...Appendix B Related service information 159...
Page 170: ...160 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 171: ...23 50 110 50 110 Appendix B Related service information 161...
Page 180: ...170 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 181: ......
Page 182: ...Part Number 49Y0073 1P P N 49Y0073...