Error Symptom
FRU/Action
Hang during Fixed Disk diagnostic
Remove the hard disk drive being tested at the time of the hang. Rerun
the diagnostic. If successful, replace the drive you removed.
Not all drives are recognized by fixed
disk diagnostic.
1. Remove first drive that does not show up and rerun diagnostic. If
remaining drives show up, replace the one that was removed.
2. If remaining drives do not show up, remove successive drives one
at a time and rerun diagnostic.
System hangs during fixed disk
diagnostic.
Remove hard drive being tested at the time of the hang and rerun the
diagnostic. If successful, replace drive that was removed.
Note:
See “System replaceable units” on page 124 to determine which components should be replaced by a field
service technician.
Symptom to FRU list
Symptom
FRU/action
Microprocessor test failed.
Microprocessor
System timer test failed.
System board
Memory test failed.
v
DIMM
v
System board
RAM refresh test failed.
System board
ECC controller logic.
System board
CMOS RAM test failed.
System board
Keyboard controller test failed.
System board
External cache test failed.
Microprocessor
PCI test failed.
System board
USB interface test failed.
System board
USB port test failed.
System board
Video test failed.
Mini-PCI video adapter
Serial port test failed.
System board
Parallel port test failed.
System board
SCSI controller test failed.
System board
Hard disk drive test failed.
1. Hard disk drive
2. Hard disk drive cable
Diskette drive test failed.
1. Diskette drive
2. Diskette drive cable
3. System board
Integrated SP test failed.
System board
System management test failed. 1. Remote Supervisor adapter, if installed.
2. System board.
CD-ROM test failed.
1. CD-ROM drive
2. CD-ROM drive cable
3. System board
Ethernet test failed.
System board
ServeRAID test failed.
RAID controller
110
IBM xSeries 225 Type 8647: Hardware Maintenance Manual and Troubleshooting Guide
Summary of Contents for 8647 - Eserver xSeries 225
Page 1: ...IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 16: ...6 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 28: ...18 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 42: ...32 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 112: ...102 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 151: ...Appendix B Related service information 141...
Page 152: ...142 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 153: ...23 50 110 50 110 Appendix B Related service information 143...
Page 154: ...144 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 155: ...Appendix B Related service information 145...
Page 166: ...156 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 167: ...Appendix B Related service information 157...
Page 169: ...Appendix B Related service information 159...
Page 170: ...160 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 171: ...23 50 110 50 110 Appendix B Related service information 161...
Page 180: ...170 IBM xSeries 225 Type 8647 Hardware Maintenance Manual and Troubleshooting Guide...
Page 181: ......
Page 182: ...Part Number 49Y0073 1P P N 49Y0073...