Changing Disk Drive Modules
In some circumstances, you can change a faulty disk drive module without the
assistance of a service representative. You can do this only if:
v
You are authorized by your organization to do this.
v
You have the correct disk drive module. Only disk drive modules that have a blue
trigger behind the handle on the front can be installed in 7133 units. The storage
capacity of a disk drive module is shown on the label at the front of the module:
Capacity
Blue
Note: Disk drive modules that can be installed in 7133 Model 010, 020, 500, or 600
units cannot be installed in 7133 Model D40 or T40 units.
Attention:
v
Do not remove two disk drive modules from the subsystem at the same time.
v
Disk drive modules are fragile. Handle them with care. Keep them well away from
strong magnetic fields.
You do not need to remove power from the 7133 unit when changing a disk drive
module.
After you have changed a disk drive module in an SSA Disk Subsystem, you must
restore it into your system using the system programs.
36
7133 Models D40 and T40 Operator Guide
Summary of Contents for 7133 D40
Page 1: ...7133 Models D40 and T40 Serial Disk Systems Operator Guide SA33 3278 02 ...
Page 2: ......
Page 3: ...7133 Models D40 and T40 Serial Disk Systems Operator Guide SA33 3278 02 ...
Page 10: ...viii 7133 Models D40 and T40 Operator Guide ...
Page 12: ...x 7133 Models D40 and T40 Operator Guide ...
Page 34: ...20 7133 Models D40 and T40 Operator Guide ...
Page 48: ...34 7133 Models D40 and T40 Operator Guide ...
Page 102: ...Command Line Tools Not applicable to PC servers 88 7133 Models D40 and T40 Operator Guide ...
Page 105: ......
Page 106: ...Part Number 34L3838 Printed in the U S A SA33 3278 02 34L3838 ...