c.
If
the
ldapsearch
search
returns
a
connection
error
,
start
a
Telnet
session
and
try
to
connect
to
the
IBM
Tivoli
Directory
Server
using
the
port
number
389.
d.
If
communication
can
be
established
with
a
Telnet
session
between
the
IBM
Tivoli
Directory
Server
and
Tivoli
Intelligent
Orchestrator,
check
the
IBM
Tivoli
Directory
Server
administrative
password.
4.
Search
the
knowledge
bases
and,
if
necessary,
contact
Support.
For
more
information,
refer
to
Appendix
B,
“Support
information,”
on
page
225.
WebSphere
Application
Server
configuration
verification:
The
following
steps
are
required:
1.
Check
the
SystemOut.log
file
for
errors.
For
more
information,
refer
to
“Problem
determination
using
SystemOut.log”
on
page
14.
2.
Verify
the
components
in
the
WebSphere
administrative
console.
If
there
are
missing
components,
search
the
knowledge
bases
and,
if
necessary,
contact
Support.
For
more
information,
refer
to
Appendix
B,
“Support
information,”
on
page
225.
Tivoli
Intelligent
Orchestrator
runtime
problem
determination
The
runtime
problem
determination
process
for
Tivoli
Intelligent
Orchestrator
can
be
divided
into
component-based
problem
determination,
and
task-based
problem
determination.
Depending
on
the
type
of
error
you
are
encountering,
you
must
determine
where
to
start
the
problem
determination
process.
v
“Component-based
problem
determination”
v
“Task-based
problem
determination”
on
page
23
Component-based
problem
determination
This
is
the
base
level
of
problem
determination
in
the
Tivoli
Intelligent
Orchestrator
runtime
environment.
After
you
isolate
the
problem
to
a
specific
component,
you
can
then
refer
to
that
component
problem
determination
method,
as
follows:
v
“DB2
Universal
Database
error
problem
determination”
v
“DB2
Universal
Database
constraint
problem
determination”
v
“IBM
Tivoli
Directory
Server
authentication
problem
determination”
on
page
22
v
“WebSphere
Application
Server
error
problem
determination”
on
page
23
DB2
Universal
Database
error
problem
determination:
If
you
have
encountered
a
DB2
Universal
Databaseerror,
follow
these
steps:
1.
If
it
is
a
DB2
Universal
Database
connection
problem,
refer
to
“DB2
Universal
Databaseconfiguration
verification”
on
page
18.
2.
If
it
is
a
constraint
error
or
exception,
refer
to
“DB2
Universal
Database
constraint
problem
determination.”
3.
If
the
problem
you
have
encountered
is
neither
a
connection
problem
nor
a
constraint
error
or
exception,
search
the
knowledge
bases
for
the
keyword
error
and,
if
necessary,
contact
Support.
For
more
information,
refer
to
Appendix
B,
“Support
information,”
on
page
225.
DB2
Universal
Database
constraint
problem
determination:
If
you
have
encountered
a
DB2
Universal
Database
constraint
error
or
exception,
follow
these
steps:
1.
Using
the
error
message
you
have
received,
identify
the
DB2
Universal
Database
table
with
the
constraint.
Chapter
2.
Problem
determination
essentials
for
Tivoli
Intelligent
Orchestrator
21
Summary of Contents for 51
Page 2: ......
Page 8: ...vi Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 46: ...34 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 50: ...38 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 56: ...44 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 90: ...78 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 102: ...90 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 106: ...94 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 232: ...220 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 236: ...224 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 246: ...234 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 247: ......
Page 248: ...Printed in USA SC32 2216 00...