Explanation:
An
error
occurred
when
the
workflow
received
as
the
input
parameter
a
software
resource
ID
that
does
not
contain
a
valid
software
module
ID.
A
valid
software
module
ID
is
required
to
identify
which
package
will
be
uninstalled
from
the
specified
system.
Operator
response:
Verify
that
the
provided
software
resource
references
the
correct
software
module.
Verify
that
the
package
was
installed
on
the
specified
system
using
a
workflow
that
implements
SoftwareInstallable.Install.
Explanation:
No
additional
information
is
available
for
this
message.
COPCOM007E
The
software
resource
with
ID
VALUE_0
does
not
have
a
valid
server
ID.
Explanation:
An
error
occurred
when
the
workflow
received
as
the
input
parameter
a
software
resource
ID
that
does
not
contain
a
valid
server
ID.
A
valid
server
ID
is
required
to
identify
the
target
system.
Operator
response:
Verify
that
the
package
was
installed
on
the
specified
system
using
a
workflow
that
implements
SoftwareInstallable.Install.
COPCOM008E
The
system
cannot
open
a
Telnet
connection
to
"
VALUE_0
".
Explanation:
The
user
setting
might
be
incorrect.
Operator
response:
From
the
command
line,
try
to
create
the
Telnet
connection
as
’userid’.
COPCOM009E
The
variable
TMA.Label_propkey
is
undefined
in
the
server
with
ID
VALUE_0
.
Explanation:
An
error
occurred
when
the
variable
TMA.Label_propkey
was
not
defined
on
the
server.
This
property
is
needed
since
it
identifies
the
IBM
Tivoli
Management
Agent
in
systems
that
have
more
than
one
agent.
The
value
of
this
property
is
the
name
of
a
second
property.
The
second
property
contains
the
name
of
the
IBM
Tivoli
Managed
Agent
label.
Administrator
Response:
Verify
that
the
server
has
a
variable
named
TMA.Label_propkey
in
the
DEPLOYMENT_ENGINE
scope.
Explanation:
No
additional
information
is
available
for
this
message.
COPCOM010E
The
third
party
software
package
with
ID
VALUE_0
does
not
have
the
required
file
name
and
file
path.
Explanation:
An
error
occurred
during
the
registration
of
the
Software
Package
Block
when
the
third
party
software
package
did
not
have
specify
the
name
and
path
of
the
Software
Package
Block.
Operator
response:
Verify
that
registration
was
performed
on
the
correct
third
party
software
package.
Administrator
Response:
Verify
that
the
third
party
software
package
was
defined
using
the
correct
file
name
and
path
attributes.
Explanation:
No
additional
information
is
available
for
this
message.
COPCOM011E
The
discovery
object
VALUE_0
does
not
have
a
valid
filter
string.
Explanation:
The
provided
discovery
object
does
not
have
the
required
property
tcm.software.filter,
tcm.hardware.pm.filter.
Those
properties
are
used
to
define
which
IBM
Tivoli
Configuration
Manager
resources
will
be
imported
into
IBM
.
The
defined
filter
value
should
be
in
the
format:
PR=PolicyRegionValue;PM=ProfileManagerValue;
SP=SoftwarePackageValue;I=True.
Operator
response:
Verify
that
the
correct
discovery
object
was
used.
Verify
that
the
discovery
object
has
the
required
filter
string
properties.
Explanation:
No
additional
information
is
available
for
this
message.
COPCOM012E
The
server
VALUE_0
does
not
have
a
locale
value.
Explanation:
An
error
occurred
in
the
workflow
because
the
server
specified
has
a
locale
value
that
is
null.
The
locale
value
is
required
to
specify
the
locale
value
of
the
items
that
will
be
imported
into
the
IBM
database.
Administrator
Response:
Verify
that
the
server
object
does
not
have
null
locale
value.
COPCOM013E
The
system
cannot
find
the
NIC
for
network
interface
IP
"
VALUE_0
".
Explanation:
This
is
a
validation
issue.
Operator
response:
Validate
the
NIC
information.
COPCOM014E
The
system
cannot
find
the
software
stack
with
ID:
"
VALUE_0
".
Explanation:
This
is
a
validation
issue.
Operator
response:
Validate
the
software
stack
information.
COPCOM015E
The
system
cannot
get
a
JNDI
context.
Explanation:
No
additional
information
is
available
for
this
message.
96
Tivoli
Intelligent
Orchestrator
Problem
Determination
and
Troubleshooting
Guide
Summary of Contents for 51
Page 2: ......
Page 8: ...vi Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 46: ...34 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 50: ...38 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 56: ...44 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 90: ...78 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 102: ...90 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 106: ...94 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 232: ...220 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 236: ...224 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 246: ...234 Tivoli Intelligent Orchestrator Problem Determination and Troubleshooting Guide...
Page 247: ......
Page 248: ...Printed in USA SC32 2216 00...