3746-900 Test Procedure
c. ____ Click on "Configuration Management".
d. ____ Double click on "Compare reference CDF-E with active
CDF-E". The active CDF-E is now being compared with the refer-
ence CDF-E
Note: If there is no difference, an information message is displayed.
Click on the "OK" pushbutton to leave the function.
If there is difference, double click on the resource in error to get more
details about that resource then:
1) Check that the cards are properly plugged.
2) Compare the configuration recorded in the CDF-E to the HONE
installation sheets.
Step
6. ___ Select Diagnostics to Test All the Resources
Note: For any unexpected message go to the START page of the
3746-900 Service Guide, SY33-2116.
a. ____ On the 3746-900 menu, click on "Problem Management"
b. ____ Double click on "Set 3746-900 Online/Offline Option", then
click on "Yes".
c. ____ Click on "OK" when the offline request has been successfully
processed.
d. ____ Press General IML on the 3746-900 control panel to set the
3746-900 offline.
Note: The 3746-900 object icon will become white, yellow, and
finally red and will stay red as long as the 3746-900 is offline.
e. ____ From the list of Problem management functions, double click on
"Perform offline Diagnostics".
f. ____ Using the radio buttons define how to run a general diagnostic.
Select Whole 3746-900 and No wrap (normally the default options),
enter the number of cycles that you want the test to run (one cycle
can take up to 15 minutes).
g. ____ Click on the "Start" pushbutton (a 'stop' pushbutton is now
visible). The normal end will be indicated by "Hardware error: 0",
00-00-0000 displayed on the 3746-900 control panel, and the 'Start'
pushbutton will be visible again.
h. ____ Click on "Cancel" to exit from the function.
Note: If the hardware error counter is incremented:
1) ____ Click on "Manage Alarms/Errors/Events (SRC's)", the
"System Reference Code Options Selection" is displayed.
2) ____ Select "Alarms" and click on "OK".
3) ____ An Alarms panel is displayed, select the last alarm (at the
top of the screen).
3-6
3746-900: Installation Guide
Summary of Contents for 3746-900
Page 1: ...3746 Nways Multiprotocol Controller Model 900 IBM Installation Guide SY33 2114 03...
Page 2: ......
Page 3: ...3746 Nways Multiprotocol Controller Model 900 IBM Installation Guide SY33 2114 03...
Page 14: ...xii 3746 900 Installation Guide...
Page 17: ...Notices xv...
Page 20: ...7 Power ON indicator 8 Emergency power OFF xviii 3746 900 Installation Guide...
Page 24: ...xxii 3746 900 Installation Guide...
Page 26: ...xxiv 3746 900 Installation Guide...
Page 40: ...3746 900 preparing for installation 1 14 3746 900 Installation Guide...
Page 102: ...3746 900 Test Procedure 3 14 3746 900 Installation Guide...
Page 146: ...Cabling the 3746 900 to the 3745 X1A 4 44 3746 900 Installation Guide...
Page 168: ...3745 Test Procedures 7 6 3746 900 Installation Guide...
Page 198: ...3746 900 Ground Bracket Installation 9 6 3746 900 Installation Guide...
Page 204: ...3746 900 Attached to a 3745 17A Ground Bracket Installation 10 6 3746 900 Installation Guide...
Page 210: ...Machine Ready for Customer 11 6 3746 900 Installation Guide...
Page 218: ...Removal the 3746 900 Attached to a 3745 17A 13 4 3746 900 Installation Guide...
Page 220: ...A 2 3746 900 Installation Guide...
Page 250: ...E 14 3746 900 Installation Guide...
Page 268: ...X 18 3746 900 Installation Guide...
Page 272: ......
Page 275: ......
Page 276: ...IBM Part Number 29H4858 Printed in Denmark by IBM Danmark A S 29H4858 SY33 2114 3...