Coax Setup Menu
Use the Coax Setup Menu to configure the coax attachment. The following table
describes the settings you can change from the Coax Setup Menu. An asterisk (*) next
to a value means it is the factory default. This menu appears only if you have the coax
attachment installed.
Notes:
1. To select a new value, press the Enter key when the value is displayed in the
message display area. An asterisk (*) appears next to the value in the message
display area, indicating that it is now active.
2. For more information about configuring the coax attachment, see
IBM Network
Printers: Twinax/Coax Configuration Guide.
3. If you are unfamiliar with using the operator panel to work with menus, please read
“Using the Operator Panel Keys” on page 30 and “Navigating Menus — Two
Examples” on page 31 before continuing.
COAX SETUP
MENU ITEM
VALUE
Description
PORT TMEOUT
nnn
Specifies the number of seconds the printer waits for data before
it determines there is no more data to receive for the job. The
printer then checks other installed attachments, and switches to
attachments with jobs waiting. nnn can be from 0 to 255. The
default is 90 seconds.
IRQ TMEOUT
nn
Specifies when an IRQ (intervention required) timeout is sent.
This tells the printer how long to wait for an intervention required
condition to be corrected before notifying the host of the error. nn
can be from 0 to 20 minutes. The default is 1 minute. 0
specifies to never send an IRQ timeout.
HLD TMEOUT
nn
Specifies the hold timeout value. This value tells the printer how
long to wait if the printer is offline for an intervention required
condition to be corrected. After this time elapses, the host is
notified of the error. nnnn can be from 0 to 20 minutes. The
default is 10 minutes. 0 specifies to never send a hold time out.
BUSY TMEOUT
nnn
Specifies the busy timeout value. This specifies the amount of
time to wait (when the printer is connected to multiple ports) for
control to be returned to the coax attachment, before notifying the
host. nnn can be from 0 to 999 minutes. The default is 20
minutes. 0 specifies to never send a busy timeout.
EAB
ENABLE*
DISABLE
Enables or disables the extended attribute buffer.
BUFFER SIZE
1920*
960
2560
3440
3564
Specifies the buffer size in bytes.
Chapter 3. Navigating Through the Operator Panel Menus
69
Summary of Contents for 24
Page 1: ...IBM Network Printer 24 IBM Network Printer 24PS User s Guide IBM S544 5378 01 ...
Page 2: ......
Page 3: ...IBM Network Printer 24 IBM Network Printer 24PS User s Guide IBM S544 5378 01 ...
Page 10: ...viii User s Guide ...
Page 12: ...x User s Guide ...
Page 16: ...xiv User s Guide ...
Page 106: ...82 User s Guide ...
Page 132: ...108 User s Guide ...
Page 162: ...138 User s Guide ...
Page 219: ...5 Plug power cord in and turn printer power back on Chapter 7 Installing Printer Options 195 ...
Page 220: ...196 User s Guide ...
Page 230: ...c9pu210 2 Use 4324 as the machine type 206 User s Guide ...
Page 238: ...214 User s Guide ...
Page 296: ...272 User s Guide ...
Page 318: ......
Page 321: ......
Page 322: ...IBM Part Number 63H4020 File Number S370 4300 9370 16 Printed in U S A S544 5378 ð1 63H4ð2ð ...