Hardware Installation
Wiring Terminals for Type 1501, 1511
Terminal
Function
1
+ 24 V DC
2
Ground 24 VDC
3
Accelerometer 1 Signal
4
Accelerometer 1 Ground
5
Alarm A
6
Alarm B
7
Alarm C
8
Alarms Set Input (Set 1)
9
Machine Speed Input (1 pulse per rev)
10
+24 V DC Supply for alarm outputs
11
Ground alarms
12
Option Analog Out 0 – 10 Volt for mm/s for input 1
13
Option Analog Out 0 – 10 Volt for gSE for input 1
14
Ground for analog outputs
15
Ground for analog outputs
16 (1
st
upper
row)
AIN 1 (analogue input 1)
17
Analog GND
18
AIN 2.
19
Analog GND
20
AIN 3 or accelerometer 2 signal
21
Analog GND or accelerometer 2 ground
22
1501, 1511: AIN4
1502, 1512: Option Analog Out 0 – 10 Volt for mm/s input 2
23
1501, 1511: Analog GND
1502, 1512: Option Analog Out 0 – 10 Volt for gSE input 2
24
DIG IN 1 (digital input 1) / Event enable
25
DIG IN 2 (elapsed hour counter)
26
DIG IN 3 (tool change counter)
27
DIG IN 4 (store)
28
DIG GND
29
CAN Ser + (Option)
30
CAN Ser – (Option)
Description of terminal connections
1: +24 V DC supply
2: Ground supply
3: Accelerometer 1 Signal. For accelerometer with 4 mA constant current supply (ICP)
4: Accelerometer 1 ground
5: Alarm output A (Opto coupler output) max. 150 mA load (supply for opto couplers terminal 10 and
11 must be connected for use of all alarm outputs).
6: Alarm Output B (see above)
7: Alarm Output C (see above)