Trend Table
From trend graph screen, click
Table of Readings
to show a numerical overview table.
Depending on the user’
s rights you can delete rows of this table. Mark the line (drag the mouse while
left button pressed), then click right and select cut data.
Click
Store Changes
and type your password
Store Trend Data to TXT File
If you want to process the trend data using other software, you can transfer the data records from the
instruments trend data memory directly to an ASCII (TXT) file. From main screen click
Read Trend
Data serial, Store to TXT File
. Watch the status line for progress messages and enter a file name
when prompted.
The file format is tab separated ASCII (TXT).
The file format is as follows:
Colon:
Content:
1
Date and Time
2
Vibration velocity in [mm/s RMS]
3
Bearing condition in [gSE]
4
Analog 1 (or velocity channel 2)
5
Analog 2 (or bearing condition channel 2)
6
Analog 3
7
Analog 4
8
Machine speed in RPM [min
-1
]
9
Status Digital inputs (Bit wise)