ibis SiViB Record 1500 Installation Instructions And Operation Manual Download Page 44

IBIS

 GmbH           

SiViB 

Record 1500 / Record Control Manual                    

      

 Page 44

 

 

IBIS

 Ingenieurbüro für Instandhaltungs- und Schwingungsmeß-Systeme GmbH 

Reinheimer Str. 17, 64846 Groß-Zimmern, Germany; www.ibis-gmbh.de 

Tel. +49 6071/42222, Fax +49 6071/71707, Email: [email protected]

 

Zoom Tool 

Hint:

 Zoom will work only with autoscaling off! 

 

Choose the required type of zoom in the selection window. 

 

 

Move the cursor it the drawing area and drag a rubber band rectangle by holding the left mouse 
button. When you release the mouse button, the area inside the rectangular will zoom in.  
 
The easiest way for zooming back out is switching back to autoscaling. 
 

Cursor Movement 

 

You can drag the cursor using the mouse or move it by clicking on one of the cursor movement 
buttons. Choose the button according to the required direction. 
 

Cursor Curve Selection 

 

 

This tool selects the curve the cursor refers to for the digital display of cursor values. 

 
 
 
 

Summary of Contents for SiViB Record 1500

Page 1: ...SiViB Record 1500 SiViB Record Control Installation Instructions and Operation Manual Version 3 1 2012...

Page 2: ...CONFIGURATION 13 Software Language and Data Path 13 Communication 13 Setup Procedure for SiViB Record 1500E 14 Online Record Control Net only 17 CONFIGURATION AND COMMISSIONING 19 NEW INSTRUMENT 19 IN...

Page 3: ...071 71707 Email info ibis gmbh de Drag Tool 43 Zoom Tool 44 Cursor Movement 44 Cursor Curve Selection 44 Graph Colors 45 RECORD CONTROL NET 46 Overview Table 47 Setting Update Rate and Time 48 Mail on...

Page 4: ...he according output will switch to alarm If meaningful an input controlling the active set of alarm setpoints can be used The machine control system can provide the information if the machine is in id...

Page 5: ...15 Ground for analog outputs 16 1st upper row AIN 1 analogue input 1 17 Analog GND 18 AIN 2 19 Analog GND 20 AIN 3 or accelerometer 2 signal 21 Analog GND or accelerometer 2 ground 22 1501 1511 AIN4...

Page 6: ...output 0 10 Volts for mm s overall of input 2 23 SiViB 1501 and 1511 Analogue input 4 SiViB 1502 and 1512 Analog output 0 10 Volts for gSE overall of input 2 Attention The analogue inputs are preconf...

Page 7: ...e per rev 10 24 V DC Supply for alarm outputs 11 Ground alarms 12 Option Analog Out 0 10 Volt for mm s for input 1 13 Option Analog Out 0 10 Volt for gSE for input 1 14 Ground for analog outputs 15 Gr...

Page 8: ...11 Ground alarms 12 Option Analog Out 0 10 Volt for mm s for input 1 13 Option Analog Out 0 10 Volt for gSE for input 1 14 Ground for analog outputs 15 Ground for analog outputs 16 1st upper row Optio...

Page 9: ...urrent probes 20 Supply for eddy current probes 24Volts max 40 mA 21 ECP1 Analog output 0 10 Volts DC for position 22 ECP1 Analog output 0 10 Volts DC for vibration 23 Out Ground for analog outputs 24...

Page 10: ...n 800 x 600 256 colors Operating System SiViB Record Control runs under Windows 98 XP Vista Win7 Installing the Software Put the CD into your CD ROM drive Click Start Run Type D English setup if your...

Page 11: ...card reader connector The driver of the card reader will find the reader automatically so you do not need to set the port manually There are other types of card readers with only the COM Port connecto...

Page 12: ...e the Quit button or the Escape key of your keyboard Avoid leaving windows open when jumping back Otherwise windows in the background might stay active and the software appears blocked or misbehaving...

Page 13: ...e required one and change the setting Choose the bus system first RS232 Choose the COM port to use with a serial null modem cross over cable for communication betreen instrument and PC The baudrate is...

Page 14: ...B The factory default IP adress is 192 168 42 50 Subnet Mask 255 255 255 0 For the PC you can use any free IP adress in the same range e g 192 168 42 1 Open your web browser and type the factory defau...

Page 15: ...serial RS232 communication The status line at the bottom of the main window shows the selected COM Port number Go to the Setup Window Click Read Setup from Instrument Allow the system 3 5 seconds to...

Page 16: ...System Options from Main Window Tab Communication Select Multi Bus System click Store Settings Password is sivib Close Record Control and reopen it This makes the changes in system options active Ple...

Page 17: ...larm set to use for the overview table Delete data in instrument after unload Deletes the data memory of the instrument after automatic unload If you are using email on alarm this avoids repeated alar...

Page 18: ...ption in live mode Logfile for communication If set to write logfile all communication telegrams sent between instrument and PC get logged to a file Attention The log file will get very large if you k...

Page 19: ...new SiViB connect the instrument to your PC using a null modem cable Connect the 24 Volts power supply and switch it on Boot your PC and start Record Control From main window select New Instrument Fil...

Page 20: ...nstrument and set the input configuration accordingly SiViB 1502 and 1512 both have a second input for an accelerometer Set line 3 for vibration mm s and line 4 for bearing condition gSE On these type...

Page 21: ...ctivation of event storage Set all inputs to active which should trigger events The button Event recording alwas on or Event recording only if DigIn1 high allows you to make event recording dependant...

Page 22: ...nsitivity Pickup sensitivity 100 coresponds to the standard input sensitivity of the input Use this for correction of sensitivity deviations of the particular sensor connected Example A particular sen...

Page 23: ...nd the correct sensitivity and offset values Calibration procedure Move the sensor to the near calibration point close to the target recommended 100 to 200 ADUs current value Measure the mechanical di...

Page 24: ...watis for interval time before the first data set is stored Then it stroes after each time interval as long as the speed window is true Interval FFT The settings for Interval Spectrum are only releva...

Page 25: ...will replace the current settings in the upper part of the window 4 Click Store changes to make the settings valid Send Setup to SiViB Important Store the settings by clicking Store Settings before yo...

Page 26: ...t to the instrument using a null modem cable Click Setup Set instrument date time The window shows both date and time from the PC and the instrument Click Send data time to instrument for synchronizin...

Page 27: ...ecord Control software In the main screen click Read Trend Data serial Watch the status bar at the bottom of the screen for messages telling you the progress of the data transfer Record Control checks...

Page 28: ...ail info ibis gmbh de Back at your PC click Memory Card in the main screen and Read data from card Wait until the status line says insert card please Plug the card into the reader with the golden cont...

Page 29: ...tion drop down box The serial number shown on the instrument s nameplate just the number without any slashes or letters other then numbers will then be shown in the serial number display box You can f...

Page 30: ...uploaded The switch Graph activates or deactivates the chart On slow PCs this can be useful when writing to file When a signal is higher then the measurement range a red over indicator will replace th...

Page 31: ...logfiles and set the switch timestamp in live files to seconds since 1904 Converting seconds since 1904 to time and date string If you want to use the live data files with a spread sheet software e g...

Page 32: ...ou have selected more then one instrument the table will have additionnal colons for the values Refer to the descrepion above for more details of the file format The advantage of the Log to file funct...

Page 33: ...ph The trend graph is useful for looking at longer term changes in the values maybe pointing at deterioration of the machine Trend graphs are based on data taken regularly under comparable conditions...

Page 34: ...Click Store Changes and type your password Store Trend Data to TXT File If you want to process the trend data using other software you can transfer the data records from the instruments trend data me...

Page 35: ...gger and the remaining 96 after the trigger This allows to see the behavior of the values right before and after the event happened Event triggering The event data sets described above will be stored...

Page 36: ...e following table Digital Inputs Byte Bit 7 6 5 4 3 2 1 0 _____ Alarm Set ___________ not used _________________ not used _______________________ not used _____________________________ DigIn1 ________...

Page 37: ...can be reset to 0 Tool Cange Counter SiViB Record has a tool change counter For each tool change a pulse of minimum 200 ms duration hast to be set on digital input 3 terminal 26 SiViB Record counts t...

Page 38: ...ed firmware 2 9 and Record Control Software Version 3 0 14 or higher The window type Bargraf shows all values of one instrument in a bargraf or tank type format The bars change colors according to the...

Page 39: ...software shows the time waveform and the FFT spectrum as soon as the transfer is completed The next measurement is then started automatically The button Measurement running Measurement stopped allows...

Page 40: ...nits 1501 1511 Input accelerometer v RMS mm s 1502 1512 Input accelerometer 1 and 2 v RMS mm s 1503 1513 1603 Input accelerometer 1 2 and 3 v RMS mm s 1532 Input eddy current probe 1 and 2 and acceler...

Page 41: ...to use the date for further examination using other programs e g Excel Any text typed in the field Comments is being stored at the beginning of the ASCII file Name and path of the file can be entered...

Page 42: ...perpendicular to each other A machine speed reference signal one pulse per rev You must use a serial connection between instrument and PC The orbit function samples the input signals from both inputs...

Page 43: ...ctical setting If however you want to zoom in to a specific part of the graph you must turn off auto scaling If the sliding switch is turned to right see picture autoscaling is on Click on the switch...

Page 44: ...ection window Move the cursor it the drawing area and drag a rubber band rectangle by holding the left mouse button When you release the mouse button the area inside the rectangular will zoom in The e...

Page 45: ...n be placed everywhere Digital display shows cursor position Snap to point or curve Cursor moves only from point to point along the curve Selection of the curve Graph Colors If you click on a line of...

Page 46: ...must have the CAN Bus option or an RS232 to Ethernet bridge fitted In a networked system all SiViB instruments are working independently and in the same manner as in a stand alone configuration Only...

Page 47: ...t points Besides the numeric value the color of the fields indicate the alarm state as follows Green O K Yellow Alarm 1 Red Alarm 2 Blue Event Alarm Grey Point inactive The overview table gets update...

Page 48: ...the software checkes for alarm conditions and creates a alarm message file These file is sent to all mail addresses set in the file Dat mailadresses txt You can open and modify this file using a word...

Page 49: ...CAN ID to a number between 1 an 255 unique for each instrument The CAN Baudrate must be the same for all instruments on the same Bus cable 125kBps is a good choice for cables of up to 400 m length Ple...

Page 50: ...to the gateway using the RS232 conectors and a nullmodem cable Start Hyperterminal by double clicking Eth_CAN ht ind the record control folder You will get a message like this Welcome at SYSTEC CAN E...

Page 51: ...plate mounting Dimensions 100 x 75 x 110 mm WxHxD Inputs Outputs 30 screw terminals 1 or 2 inputs for accelerometers ICP supply sensitivity 10 100 or 500 mV g 4 or 2 inputs for DC Volts 0 10 Volts or...

Page 52: ...eter 100 mV g 2 inputs for eddy current probes 8 mV m SiV01 032 SiViB Record Control Light Configuration software for Windows free with instrument SiV09 030 SiViB Record Control Pro For configuration...

Page 53: ...The Record Control Software uses drivers for the card reader which are instrument specific Therefore it is not possible to use other card readers presently Question On my SiViB the red LED Card Error...

Reviews: