4. Operation of SEP
Related Controllers
217
4) Inching (Use the arrow keys [Inching-] and [] to inch the actuator to the target
position and then acquire the achieved position (current position) as the forward end position
or backward end position).
An example of operation mode 0 (standard movement between 2 points) is explained.
How to acquire the current position, 30.0 mm, as the backward end position is explained.
No. Operation
Screen
Remarks
1 On the SEP menu screen:
Touch [Pos.Edit].
2 If the position data edit
password is other than
“0000,” the password input
screen appears.
Input a position data edit
password and touch [ENT].
You can set a position data
edit password from “Position
edit password” on the
parameter edit screen.
3 Set the position, acceleration
and deceleration relating to
the backward end position.
Touch [Backward Position].
Touch [Menu] to return to the
SEP menu screen.
4 Touch [Jog].
Touch [Menu] to return to the
position setting screen.
* Perform home return if not
already completed.
5 If the servo is off, touch [SV
ON] to turn on the servo.
6 Touch [Inching].
The display switches to the
inching screen.
Touch [Menu] to return to the
itemized position setting
screen.