3. Operation of CON Related Controllers
95
Output
Signal
name
Content
NC(-)
Feature not assigned
MOVE Moving signal
: It turns ON during actuator movement process
SV
Operation preparation end : Servo turned on when ON
HEND
Home return completion : Home-return command when ON
* ALM
Alarm : It turns ON when an alarm is generated
ZONE1
ZONE : It turns ON when the current position is in the zone setting
ZONE2
ZONE 2 : It turns ON when the current position is in the zone setting
PZONE
Position zone : It turns ON when the current position is in the position zone
setting
* EMGS
Emergency stop : It turns ON when in emergency stop status.
RMDS
Operation Mode Condition : It turns off when the current condition is in AUTO
Mode and on when in MANU Mode
LOAD
Load Output Judgment : It turns ON when reached and OFF when not reached
TRQS
Torque level
: It turns ON when reached and OFF when not reached
PSFL Pressing and a miss : It turns ON when miss-pressing occurred
PWR
Controller ready
: It turns ON when it is ready
CM1, CM2,
CM4, CM8
With the combination of the output of these signals, the current command current
rate (ratio to the rated value) should be output.
* In order to output the command current rate, it is necessary that all of the four
signals, CM1, CM2, CM4 and CM are assigned. With this as a reason, it is
available only when the number of positioning points is either four points or
eight points.
• PCON-CYB outputs the current load current in every 6.25% period.
• ACON-CYB and DCON-CYB output the current load current in every 18.75%
period.
PUSH
In Pressing Process
: It turns ON during pressing process
GHMS
In Home-Return Process
: It turns on during home-return process
* ALMC
Critical Malfunction Status : It turns off when an alarm occurred which disables
operation to be continued (It is necessary to reboot
the power)
MEND
It turns on when positioning is complete, pressing is complete or miss-pressing is
occurred and turns off when operation started
* OVLW
Overload Warning Signal : It turns on when the estimated motor temperature
exceeds the setting and turns off when it falls below
the setting
* ALML
Light Malfunction Status
: It turns off when an alarm occurred for light
malfunction which operation is still possible to
continue
(Note) “*” in the symbol names above shows signals in active low.