52
(4) RMA type
High-speed type
Maximum current-limiting value
Low-speed type
65%
Medium-speed type
70%
High-speed type
70%
Note: The accuracy of push force at standstill is not guaranteed. The above graphs are provided for
reference purposes only. If the push force is too small, malfunction may occur during push &
hold operation due to slide resistance, etc., so exercise caution.
The maximum current-limiting value is shown in the above graphs. The minimum value is 20%.
900
800
700
600
500
400
300
200
100
0
500
400
300
200
100
0
20 30 40 50 60
65
20 30 40 50 60 70
300
250
200
150
100
50
0
20 30 40 50 60 70
Low-speed type
Medium-speed type
Push for
ce
(N
)
Push for
ce
(N
)
Current-limiting value (%)
Current-limiting value (%)
Push for
ce
(N
)
Current-limiting value (%)