24
4.2.2 External
Connection
Diagram
An example of standard wiring is shown below.
MPI
MPO
SIO
1 (SGA)
2 (SGB)
3 (+5V)
4
5 (EMGA)
6 (+24V)
7 (GND)
8 (EMGB)
RCP2-CG
S1
S2
24V
N
FG
PIO
MOT
A1 (A)
A2 (VMM)
A3 (B)
B1 (A)
B2 (VMM)
B3 (B)
ENC
9 (ENB)
1 (FG)
5 (GND)
6 (5V)
11 (ENA)
12 (ENA)
10 (ENB)
13 (BK-)
14 (BK+)
M
PG
Blue
Black
White
Red
Black
Green
GND
24V
Orange (black 2)
Orange (red 2)
Yellow (black 1)
Yellow (red 1)
White (black 1)
White (red 1)
Light blue
(black 1)
Light blue
(red 1)
Motor drive-
power cutoff
circuit
Controller
Connected to teaching
pendant or PC
Input power supply
24 VDC
24V
0V
FG
Host system
<PLC>
I/O flat cable
Refer to 4.3, “Connecting the
I/O Cables,” for the
connection of I/O signals.
(PORT switch)
Actuator
Motor
Encoder
Holding
brake
Brake release switch
Terminal block