I
NTELLIGENT ACTUATOR
34
10) Attach the motor cover.
Then, connect the motor connector and encoder connector and fasten the motor earth cable with M3 bolt.
11) Attach the cable protection cover.
At that time, take care not to catch the cable.
12) Attach the pulley cover.
13) Connect the relay cable and turn on the power to the controller. Then, perform the homing operation from the personal
computer or teaching pendant.
(In the case that the absolute encoder has been mounted, the absolute reset is required).
Confirm the deviation from the original home position. If there is any deviation, adjust it using the home offset value in
the parameters.