18
i3-TRNG-CAMS-
68R_78R
.indd
Rev.
150505
5. Feed the camera cabling through the
ridgid pipe bracket.
6. Slide the protruding mounting screws
through three matching mounting
screw holes on the camera body and
rotate the camera clockwise to secure
the camera body on the mounting
surface. Use a Phillips screwdriver to
tighten three mounting screws in place.
7. Replace the camera cover.
Match up the safety lock screw with
the screw hole on the camera body,
then push straight down onto the
camera cover to engage the clips.
The camera cover will re-attach.
8. Use a Phillips screwdriver to
re-tighten the safety lock screw.
Use
silicone
to maintain IP66
rating
DB78BB - Back box
Safety lock screw
3/4” Electrical EMT
Conduit Fitting
Ridgid 3/4” pipe
Use
silicone
to maintain IP66
rating
DB78BB - Back box
Safety lock screw
3/4” Electrical EMT
Conduit Fitting
Ridgid 3/4” pipe
Use
silicone
to maintain IP66
rating
DB78BB - Back box
Safety lock screw
3/4” Electrical EMT
Conduit Fitting
Ridgid 3/4” pipe