15
Install vertically
Rack mount bracket WV-QRM001 (option) is required when installing the product vertically.
Important:
• Rack mount bracket (WV-QRM001) does not guarantee that the product will not tip over.
Step 1
Use a screwdriver to remove the screw at the front of
the right side face.
Remove the screw on the front right side
Keep the removed screws (M3 × 6 mm) securely.
Step 2
With the right side of the product facing down, install
the rack mound bracket (WV-QRM001: option) and
rubber foot.
Secure with rack mount bracket fixing screws (2 pcs.)
(included with WV-QRM001).
• Screw tightening torque:
0.59 N·m to 0.78 N·m (6.0 k
g
f·cm to 8.0 k
g
f·cm)
{0.43 lbf·ft - 0.58 lbf·ft}
Attach the rubber foot that is included with the WV-QRM001
to the position as shown in the illustration.
Note:
• Use the following standard accessories included with the
WV-QRM001 rack mount bracket.
Rack mount bracket × 1
Rack mount bracket fixing screws (M3 × 10 mm) × 2
Rubber foot × 1
• This product can be mounted upside down, but the
distance from the product to the edge of the rack mount
bracket should be the same on both sides.
Rack mount bracket fixing screws × 2
(M3 × 10 mm: included with WV-QRM001)
Rubber foot × 1
(Included with WV-QRM001)
Attachment position of the rubber foot
13 mm {1/2 inches}
22 mm {7/8 inchis}
Important:
• The operating temperature range of the product is 0 °C
to +45 °C.
* HDDs deteriorate at high temperatures, affecting their
service life. It is recommended that the product
(including the AC adapter) be used at a temperature of
about +25 °C.
2
Installation
(continued)